نتایج جستجو برای: 2d and 3d dimensional radiotherapy

تعداد نتایج: 16973860  

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2005
Alongkarn Chutinan Sajeev John

We demonstrate on-chip, single-mode, waveguiding of light in air for a variety of 2D-3D photonic band gap (PBG) heterostructures. These include square spiral, woodpile, slanted pore, and inverse opal three-dimensional (3D) photonic crystals intercalated with a 2D (planar) photonic crystal microchip. Design rules are established to yield maximal single-mode waveguiding bandwidths of up to roughl...

Journal: :Medical physics 2005
S Steciw B Warkentin S Rathee B G Fallone

A three-dimensional (3D) intensity-modulated radiotherapy (IMRT) pretreatment verification procedure has been developed based on the measurement of two-dimensional (2D) primary fluence profiles using an amorphous silicon flat-panel electronic portal imaging device (EPID). As described in our previous work, fluence profiles are extracted from EPID images by deconvolution with kernels that repres...

Journal: :Acta orthopaedica Belgica 2015
Kazunari Ishida Akihiko Toda Nao Shibanuma Tomoyuki Matsumoto Ryosuke Kuroda Masahiro Kurosaka

This study aimed to compare two-dimensional (2D) and three-dimensional (3D) methods for evaluating implant alignment in navigated UKA. Nineteen UKAs in 18 subjects (7 men) were performed using an image-free navigation system. Coronal and sagittal implant alignments were assessed using radiographs (2D evaluation) and 3D image-matching software. The accuracy of 2D evaluation was compared with tha...

Journal: :Echocardiography 2009
Preeti Singh Jayaprakash Manda Ming Chon Hsiung Anjlee Mehta Saritha Kumari Kesanolla Navin C Nanda Shen-Kou Tsai Jeng Wei Wei-Hsian Yin

Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as c...

Journal: :JACC. Cardiovascular imaging 2015
Thor Edvardsen Kristina H Haugaa

T he ability to imagine a 3-dimensional (3D) image of the heart was one of the earliest recognized benefits of 2-dimensional (2D) echocardiography at its inception 40 years ago. The ability to build such an image in real time has been a remarkable feat of image processing in the past decade. Intuitively, 3D imaging is the future of echocardiography, and the superiority of this method compared w...

2016
Jacopo Antonello Emil B. Kromann Daniel Burke Joerg Bewersdorf Martin J. Booth

Stimulated emission depletion (STED) microscopes, like all super-resolution methods, are sensitive to aberrations. Of particular importance are aberrations that affect the quality of the depletion focus, which requires a point of near-zero intensity surrounded by strong illumination. We present analysis, modeling, and experimental measurements that show the effects of coma aberrations on deplet...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شاهد - دانشکده فنی و مهندسی 1387

abstract biometric access control is an automatic system that intelligently provides the access of special actions to predefined individuals. it may use one or more unique features of humans, like fingerprint, iris, gesture, 2d and 3d face images. 2d face image is one of the important features with useful and reliable information for recognition of individuals and systems based on this ...

Journal: :Tumori 2013
Maria Antonietta Gambacorta Danilo Pasini Bruce Daniel Minsky Stefano Arcangeli Alice Mannocci Maria Cristina Barba Brunella Barbaro Stefania Manfrida Mario Balducci Vincenzo Valentini

BACKGROUND AND AIM To assess the effectiveness of the potential advantages with 3-dimensional-based treatment planning versus 2-dimensional pelvic bone-based treatment planning in patients with rectal cancer, controlled for clinical stage. METHODS AND MATERIALS Areas at risk from computed tomography in 30 patients were delineated: mesorectum, presacral, internal iliac, obturator and external ...

2012
Z. Mohd Zin Zalhan Mohd Zin

The Self Organizing Maps (SOM) is regarded as an excellent computational tool that can be used in data mining and data exploration processes. The SOM usually create a set of prototype vectors representing the data set and carries out a topology preserving projection from high-dimensional input space onto a low-dimensional grid such as two-dimensional (2D) regular grid or 2D map. The 2D-SOM tech...

Journal: :European journal of public health 2015
Hyun-Ghang Jeong Young-Hoon Ko Changsu Han So-Young Oh Kun Woo Park Taehee Kim Deokwon Ko

BACKGROUND Watching three-dimensional television (3D TV) may strain the eyes. However, other potential harmful effects of 3D TV watching have been rarely investigated. The current study examined the impact of 3D TV watching on neurophysiological responses and cognitive functioning as compared with two-dimensional TV (2D TV) watching. METHODS A total of 72 individuals were randomly assigned to...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید