نتایج جستجو برای: 3d film dosimetry dvh

تعداد نتایج: 284641  

2017
Davide Cusumano Maria Luisa Fumagalli Francesco Ghielmetti Linda Rossi Giuliano Grossi Raffaella Lanzarotti Laura Fariselli Elena De Martin

Gafchromic EBT3 film dosimetry in radiosurgery (RS) and hypofractionated radiotherapy (HRT) is complicated by the limited film accuracy at high fractional doses. The aim of this study is to develop and evaluate sum signal (SS) film dosimetry to increase dose resolution at high fractional doses, thus allowing for use of EBT3 for dose distribution verification of RS/HRT treatments. To characteriz...

2017
Kalin I Penev Meng Wang Kibret Mequanint

Tetrazolium salts (TS) have been previously used for radiochromic dosimetry in solutions, films and three dimensional (3D) gelatine-based gels. However, widespread application for 3D dosimetry has not been achieved due to the required high concentrations and associated high costs of the TS dimer used in prior research. Through careful selection of TS monomer, sensitivity-enhancing additives and...

2008
Hiroko Ohuchi Mitsuya Abe

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...

Journal: :Physics in medicine and biology 2001
M J Butson T Cheung P K Yu

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate ...

2012
Yi Wang Wei-Jun Ye Le-Hui Du Ai-Ju Li Yu-Feng Ren Xin-Ping Cao

Currently, image-based 3-dimentional (3D) planning brachytherapy allows for a better assessment of gross tumor volume (GTV) and the definition and delineation of target volume in cervix cancer. In this study, we investigated the feasibility of our novel computed tomography (CT)-guided free-hand high-dose-rate interstitial brachytherapy (HDRISBT) technique for cervical cancer by evaluating the d...

2013
F Nordström

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4 dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept o...

2014
Mauro Valente José Vedelago

Fricke gel dosimetry is a valuable method for in-phantom dose measurements in complex irradiation modalities like IMRT and BNCT. Implementation of this dosimetry technique requires dedicated instruments capable of measuring and further analysis immediately in situ at the radiation facility. This work presents a novel and integral dosimetry system aimed to attain portability requirements. The me...

Journal: :Journal of radiation research 2012
Katsumi Shima Kunihiko Tateoka Yuichi Saitoh Junji Suzuki Yuji Yaegashi Kazunori Fujimoto Takuya Nakazawa Akihiro Nakata Tadanori Abe Sho Imai Kouichi Sakata Masato Hareyama

The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film...

2014
Juan F. Calvo‐Ortega Tony Teke Sandra Moragues Miquel Pozo Joan Casals

In the present study, we describe a method based on the analysis of the dynamic MLC log files (DynaLog) generated by the controller of a Varian linear accelerator in order to perform patient-specific IMRT QA. The DynaLog files of a Varian Millennium MLC, recorded during an IMRT treatment, can be processed using a MATLAB-based code in order to generate the actual fluence for each beam and so rec...

2013
M Oldham J Newton L Rankine J Adamovics D Kirsch S Das

There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precision x-Ray using high resolution 3D dosimetry techniques. Initial results revealed a significant tar...