E Jalalian, S Koosha, S Safari, S Zandrahimi,

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

Journal: :The International journal of oral & maxillofacial implants 2002
Kivanç Akça Haldun Iplikçioğlu Murat C Cehreli

PURPOSE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations. While the functional life spans of these cements are unpredictable, the relative retentiveness of various permanent and provisional cements between dental alloys and titanium abutments is not well documented. The aim of this study was to compare the uniaxial resistance force...

2012
Izabela Cristina Maurício Moris Adriana Cláudia Lapria Faria Maria da Gloria Chiarello de Mattos Ricardo Faria Ribeiro Renata Cristina Silveira Rodrigues

PURPOSE The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment. MATERIALS AND METHODS Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their res...

2016
Albano Porto da Cunha Jr Glauco Pereira Moysés Ana Christina Claro Neves Rafael Pino Vitti Flávia Cardoso da Rosa Goulart Laís Regiane da Siva-Concílio

Objective The study evaluated the influence of abutment design on the retention of implant-cemented metal copings. Material and methods Two abutments of the same system with the same indications, height and the total occlusal convergence, but of different designs were evaluated. Ten RN synOcta abutments (Straumann, Waltham, MA) and ten RN titanium solid abutments (Straumann, Waltham, MA) were t...

Journal: :Clinical oral implants research 2017
Francine D Brandenberg Irena Sailer Vincent Fehmer Dominik L E Büchi Christoph H F Hämmerle Daniel S Thoma

OBJECTIVE To test whether or not pink veneering of the submucosal part of zirconia abutments influences clinical, microbiological and histological outcomes of cemented implant-supported single crowns (ISSC). MATERIALS AND METHODS A total of 20 patients with one single-tooth implant in the esthetic zone were included. Implants were randomly restored with either pink-veneered zirconia abutments...

2016
Paulo J. Almeida Cesar L. Silva Jorge L. Alves Filipe S. Silva Ramiro C. Martins João Sampaio-Fernandes

Objectives: Although implant abutments made of yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) show great predictability, some issues related to its aging require further study. The objective of this in vitro study is to assess the stability of 3Y-TZP zirconia implant abutments with two different implant connections when subjected to aging simulation through thermocycling and mechani...

Journal: :The Journal of prosthetic dentistry 2016
Chandur P K Wadhwani Richard O'Brien Mathew T Kattadiyil Kwok-Hung Chung

Titanium alloys are used for implant abutments onto which prostheses are attached. One major disadvantage of titanium abutments is their esthetics; the metallic gray color may show through the restorative material or through surrounding tissues. A laboratory technique using readily available household items is described that can alter the abutment color by anodization.

Journal: :Journal of Prosthetic Dentistry 2021

Statement of problem How processing by computer-aided design and manufacturing (CAD-CAM) or traditional chairside fabrication techniques affects the presence defects mechanical properties interim dental prostheses is unclear. Purpose The purpose this in vitro study was to compare effects CAD-CAM versus material on fracture biomechanical behavior 4-unit with without a cantilever. Material method...

2013
Eun-Cheol Keum Soo-Yeon Shin

PURPOSE This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive cementation. MATERIALS AND METHODS Forty implant fixture analogues and abutments were embedded in resin blocks. Forty cast crowns were fabricated and divided into 4 groups each containi...

Journal: :Brazilian dental journal 2014
Deceles Cristina Costa Alves Paulo Sérgio Perri de Carvalho Elizabeth Ferreira Martinez

The objective of this study was to evaluate the bacterial seal at the implant-abutment interface using two morse taper implant models, by means of an in vitro microbiological analysis. For that were used 15 implants with mini-abutments tightened by friction, no screws (Group 1); and 30 implants with screw-tightened abutments, of which 15 received 20 N.cm of closing torque (Group 2) and the othe...

نمودار تعداد نتایج جستجو در هر سال