نتایج جستجو برای: amperometric

تعداد نتایج: 2460  

Journal: :Biosensors & bioelectronics 2013
Cheng Xue Qing Han Yang Wang Jinhua Wu Tingting Wen Ruoyu Wang Junli Hong Xuemin Zhou Huijun Jiang

In this work, a highly sensitive and selective biomimetic electrochemical sensor for the amperometric detection of trace dopamine (DA) in human serums was achieved by gold nanoparticles (AuNPs) doped molecularly imprinted polymers (MIPs). Functionalized AuNPs (F-AuNPs), a novel functional monomer bearing aniline moieties on the surface of the AuNPs, were prepared via a direct synthesis method a...

2010
Irja Helm Lauri Jalukse Ivo Leito

This tutorial focuses on measurement uncertainty estimation in amperometric sensors (both for liquid and gas-phase measurements). The main uncertainty sources are reviewed and their contributions are discussed with relation to the principles of operation of the sensors, measurement conditions and properties of the measured samples. The discussion is illustrated by case studies based on the two ...

2015
Mauro Tomassetti Elisabetta Martini Luigi Campanella Gabriele Favero Gabriella Sanzó Franco Mazzei

A detailed comparison was made of the analytical features of a new Surface Plasmon Resonance (SPR) immunodevice for triazine pesticide determination with those of two other amperometric (conventional and screen-printed) immunosensors and the advantages and disadvantages of the SPR method were thoroughly investigated. For conventional amperometric and screen-printed devices, "competitive" assays...

2010
Zhiwei Zhao Wei Lei Xiaobing Zhang Baoping Wang Helong Jiang

Nanostructured ZnO with its unique properties could provide a suitable microenvironment for immobilization of enzymes while retaining their biological activity, and thus lead to an expanded use of this nanomaterial for the construction of electrochemical biosensors with enhanced analytical performance. ZnO-based enzyme electrochemical biosensors are summarized in several tables for an easy over...

2015
Mauro Tomassetti Maruschka Serone Riccardo Angeloni Luigi Campanella Elisa Mazzone

The aim of this research was to test the correctness of response of a superoxide dismutase amperometric biosensor used for the purpose of measuring and ranking the total antioxidant capacity of several systematically analysed mixed berries. Several methods are described in the literature for determining antioxidant capacity, each culminating in the construction of an antioxidant capacity scale ...

Journal: :Artificial cells, blood substitutes, and immobilization biotechnology 2010
Mustafa Kemal Sezgintürk Dilek Odaci Nurdan Pazarlioğlu Roberto Pilloton Erhan Dinçkaya Azmi Telefoncu Suna Timur

Amperometric biosensors using laccase from Trametes versicolor as a bioelement were developed for 2,4-dichloro phenoxy acetic acid (2,4-D). Laccase enzyme was immobilized by gelatin and glutaraldehyde onto a Clark oxygen probe and screen printed electrodes (SPEs). Amperometric and chronoamperometric measurements were carried out with the biosensors. First, the effect of laccase activity on the ...

Journal: :The Journal of biological chemistry 1963
A RIGGS

Previous work (1, 2) suggested that a relationship might exist between the number of reactive cysteine residues in various mammalian hemoglobins and the body weight of the animal from which the hemoglobin comes. These studies depended on amperometric titration of the deoxygenated hemoglobin with mercuric ions. The number of mercuric ions bound per molecule ranged from 1.29 for elephant hemoglob...

2009
Alex S. Lima Nerilso Bocchi Homero M. Gomes Marcos F. S. Teixeira

The participation of cations in redox reactions of manganese oxides provides an opportunity for development of chemical sensors for non-electroactive ions. A sensor based on a nanostructured hollandite-type manganese oxide was investigated for voltammetric detection of potassium ions. The detection is based on the measurement of anodic current generated by oxidation of Mn(III) to Mn(IV) at the ...

2012
Yejin Ha Misun Kim Jiseon Nah Minah Suh Youngmi Lee

Location-dependent skin surface's partial nitric oxide pressure (pNO) is studied using highly sensitive amperometric NO microsensor with a small sensing area (diameter  = 76 μm). The pNO level of LI4 (Hegu) acupuncture point is measured and compared with the pNO level of nonacupuncture point. In addition, the mapping of pNO is carried out over the left wrist skin area one- as well as two-dimens...

2010
Silvia Sanllorente-Méndez Olga Domínguez-Renedo María Julia Arcos-Martínez

Enzymatic amperometric procedures for measuring arsenic, based on the inhibitive action of this metal on acetylcholinesterase enzyme activity, have been developed. Screen-printed carbon electrodes (SPCEs) were used with acetylcholinesterase covalently bonded directly to its surface. The amperometric response of acetylcholinesterase was affected by the presence of arsenic ions, which caused a de...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید