نتایج جستجو برای: baffle design
تعداد نتایج: 960903 فیلتر نتایج به سال:
Reinforcing speech levels and controlling noise and reverberation are the ultimate acoustical goals of lecture-room design to achieve high speech intelligibility. The effects of sound absorption on these factors have opposite consequences for speech intelligibility. Here, novel ceiling baffles and reflectors were evaluated as a sound-control measure, using computer and 1/8-scale models of a lec...
We report a methodology for enhancing the mass transfer at the anode electrode of sediment microbial fuel cells (SMFCs), by employing a fabric baffle to create a separate water-layer for installing the anode electrode in sediment. The maximum power in an SMFC with the anode installed in the separate water-layer (SMFC-wFB) was improved by factor of 6.6 compared to an SMFC having the anode embedd...
Abstract Simulation of erosion wear and design optimization have been performed for a convective gas cooler with helical coil. Based on the results simulation standard flat baffle used in Shell gasification-based combined cycle unit, it is concluded that particle impact angle main factor determining maximum. To reduce erosion, necessary to install structural element instead align flow path ash ...
A novel instrumented baffle surrounding the suspended end mirror in input mode cleaner cavity of Virgo interferometer was installed Spring 2021. Since then, device has been regularly operated experiment, and data collected show good stability. The will operate upcoming O4 observation run, serving as a demonstrator technology designed to instrument baffles front main mirrors time for O5. In this...
OBJECTIVES Rhythm disturbances are an important cause of morbidity in Fontan patients. Currently, the total cavopulmonary connection is performed by using the intra-atrial lateral tunnel (ILT) ('baffle ILT' or 'prosthetic ILT'), or the extracardiac conduit (ECC). The aim of the study was to evaluate rhythm abnormalities and compare the surgical techniques in a contemporary cohort. METHODS In ...
OBJECTIVE Establishment of Fontan circulation in complex univentricular hearts often requires several surgical procedures. We developed a procedure which maintains the advantages of a staged approach, however, during the initial surgery additional preparatory measures are performed to allow subsequent non-surgical Fontan completion. METHODS The operation is a lateral baffle Fontan procedure. ...
The transition to Advanced LIGO introduces new sensitivity requirements for the LIGO interferometers. When light scatters away from the main laser beam, then scatters off the beam tube and returns to the main beam, noise is introduced into the phase of the laser. The Auxiliary Optics Support subsystem uses baffles and beam dumps to control this scatter, but the baffle material and shape contrib...
Neurobiologie angefertigt. " 'Hard-eyed' creatures and insects manifestly assume the posture of sleep; but the sleep of all such creatures is of brief duration, so that often it might well baffle one's observation to decide whether they sleep or not. " (Aristoteles, On Sleep and Sleeplessness 350 BC)
A five-year-old girl with partial anomalous pulmonary venous connection to the azygous vein with intact atrial septum is reported. The clinical and roentgenographic features suggested the correct diagnosis. Surgical correction of this previously unreported defect was accomplished by creating an atrial septal defect and constructing a baffle to direct the blood flow from the azygous vein to the ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید