نتایج جستجو برای: beam hardening
تعداد نتایج: 122991 فیلتر نتایج به سال:
This study aimed to investigate the effect of electron beam welding parameters on the microstructural characteristics and mechanical properties of the dissimilar joint between 17-4PH precipitation hardening stainless steel and Ti6Al4V alloy. For this purpose, the welding of these two alloys was done without an interlayer and with an interlayer of copper with a thickness of 0.8 mm. Two different...
Powder bed fusion processes based additively manufactured SS 316L components fall short of surface integrity requirements needed for optimal functional performance. Hence, machining is required to achieve dimensional accuracy and enhance characteristics. This research focused on comparing the material removal performance produced by PBF-LB (laser) PBF-EB (electron beam) in terms tool wear integ...
This paper derives kinematic admissible bending moment – axial force (M-P) interaction relations for mild steel by considering strain hardening idealisations. Two models for strain hardening – Linear and parabolic have been considered, the parabolic model being closer to the experiments. The interaction relations can predict strains, which is not possible in a rigid, perfectly plastic idealizat...
در این پایان نامه در فصل دوم به معرفی و بررسی ویرانی پیش رونده در ساختمان ها از نگاه آییین نامه های مختلف پرداخته می شود و سپس تفاوت های سازه مقاوم در برابر انفجار و مقاوم در برابر ویرانی پیش رونده معرفی می گردد. در ادامه با توجه به شدت تخریب اولیه در سازه آیین نامه ufc بررسی شد.سپس آئین نامه های مربوط به طراحی مقاوم در برابر ویرانی پیش رونده و روش های کلی طراحی سازه ها توضیحاتی در مورد نحوه حذ...
Four methodologies were evaluated for quantifying kilovoltage cone-beam computed tomography (CBCT) dose: the Cone-Beam Dose Index (CBDI), IAEA Report 5 recommended methodology (IAEA), the AAPM Task Group 111 methodology (TG111), and the current dose metric; the Computed Tomography Dose Index (CTDI) on two commercial Varian cone-beam CT imaging systems; the Clinac iX On-Board Imager (OBI); and t...
Most small-animal X-ray computed tomography (CT) scanners are based on cone-beam geometry with a flat-panel detector orbiting in a circular trajectory. Image reconstruction in these systems is usually performed by approximate methods based on the algorithm proposed by Feldkamp et al. (FDK). Besides the implementation of the reconstruction algorithm itself, in order to design a real system it is...
The 6 MV flattening filter-free (FFF) beam has been commissioned for use with compensators at our institution. This novel combination promises advantages in mitigating tumor motion due to the reduced treatment time made possible by the greatly increased dose rate of the FFF beam. Given the different energy spectrum of the FFF beam and the beam hardening effect of the compensator, the accuracy o...
In the field of resonant NEMS design, it is a common misconception that large-amplitude motion, and thus large signal-to-noise ratio, can only be achieved at the risk of oscillator instability. In the present paper, we show that very simple closed-loop control schemes can be used to achieve stable largeamplitude motion of a resonant structure, even when jump resonance (caused by electrostatic s...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید