نتایج جستجو برای: breast average dose
تعداد نتایج: 907628 فیلتر نتایج به سال:
background: pulmonary complications of radiation to breast are inevitable, while its incidence and severity are not clear. one of the methods to assess pulmonary complications is spirometry. the influence of radiotherapy on pulmonary function test and the factors affecting it have been assessed in this study. methods: breast cancer patients with stage ii and iii (based on tnm staging), underwen...
Mammography is the safest method of detecting breast cancer but, at the same time, the most exacting radiological examination which implies getting high quality images and a minimum dose per breast. The present study was carried out in six mammography laboratories, from which only one has partially implemented a programme of quality control. There were evaluated the phantom image, film contrast...
background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...
AbstractIntroduction Silicone gel breast implants are used for breast reconstruction post mastectomy. In the event of cancer recurrence, the radiation oncologists are forced to irradiate through the prosthesis device. Due to prosthesis higher atomic number dose perturbations occur during treatment. This study determined the influence of silicone gel thickness on the photon beam distribution. Ma...
3 PURPOSE: The aim of this study was to investigate how the diagnostic accuracy in digital mammography is affected by dose to the breast. MATERIAL AND METHODS: Structures resembling invasive tumours and microcalcifications on x-ray images were positioned in an anthropomorphic breast phantom equivalent to a 50 mm compressed breast containing 50% glandular tissue. The average glandular dose based...
Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients. Materials and Methods: Co...
The objective of this work is to evaluate the interfractional biological effective dose (BED) variation in MammoSite high dose rate (HDR) brachytherapy. Dose distributions of 19 patients who received 34 Gy in 10 fractions were evaluated. A method was employed to account for nonuniform dose distribution in the BED calculation. Furthermore, a range of alpha/beta values was utilized for specific c...
Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...
background: breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. it is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. materials and methods: in this study two mammography machines located at said-al shohada (giotto) and shah...
Aromatase inhibitors (AI) profoundly suppress estrogen levels in postmenopausal women and are effective in breast cancer prevention among high-risk postmenopausal women. Unfortunately, AI treatment is associated with undesirable side effects that limit patient acceptance for primary prevention of breast cancer. A double-blind, randomized trial was conducted to determine whether low and intermit...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید