نتایج جستجو برای: cod removal efficiency was raised up to 635

تعداد نتایج: 10977348  

ژورنال: سلامت و محیط زیست 2011
ابراهیمی, اصغر, احرامپوش, محمد حسن, مختاری, مهدی, کریمی, بهروز,

  Backgrounds and Objectives: Wet air oxidation (WAO) is one of the advanced oxidation process which is mostly used to reduce organic matter concentration from industrial wastewater, toxic and non biodegradable substance and solid waste leachate.The objective of this paper is comparisons of three advance oxidation in organic matter removal in different conditions from Esfahan composing factory...

Journal: :محیط شناسی 0
امیرحسام حسنی استادیار دانشکده محیط زیست و انرژی ، واحد علوم وتحقیقات دانشگاه آزاد اسلامی ایمان حسین زاده دانشجوی کارشناسی ارشد مهندسی محیط زیست، دانشکده محیط زیست و انرژی، واحد علوم وتحقیقات دانشگاه آزاد اسلامی بهزاد ترابی فر کارشناس ارشد مهندسی محیط زیست، دانشکده محیط زیست ، دانشگاه تهران

in this research the operation of fixed activated sludge system for treatment of wastewater containing heavy metal compounds, by use of fas pilot ,a plaxy glass tank with three section; these section are downward-flow aerated reactor, upward-flow aerated reactor and gravity sediment unit, length and width and height of each part was respectively 15.7cm, 31.5cm , 51.5 cm and feeding with the syn...

Journal: :Water science and technology : a journal of the International Association on Water Pollution Research 2010
C L S Rodrigues A H Mounteer T V Stoppa L C Dalvi

In order to meet increasingly strict Brazilian COD emissions limits, mills must understand the components that contribute to effluent COD, how these vary between normal mill operation and maintenance shutdowns, and how this variation affects treatment efficiency. To this end, primary and secondary effluents from a Brazilian bleached eucalypt kraft pulp mill activated sludge system were analyzed...

2017
Yanan Ren Fernanda Ferraz Abbass Jafari Kang Qiuyan Yuan

Background Aerobic granular sludge has become an attractive alternative to the conventional activated sludge due to its high settling velocity, compact structure, and higher tolerance to toxic substances and adverse conditions. Aerobic granular sludge process has been studied intensively in the treatment of municipal and industrial wastewater. However, information on leachate treatment using ae...

ژورنال: سلامت و محیط زیست 2013
خسروی, رسول, لیلی, مصطفی, موسوی, غلامرضا , ندافی, کاظم ,

Background and Objectives: Furfural with a chemical formula of C5H4O2 is a toxic and hazardous substance for human and environment. Furfural and its derivatives such as furfuryl alcohol, alone or in combination with phenol, acetone or urea are used mainly in the production of resin. The second major application of furfural is in the production of solvents such furan and tetrafuran frequently us...

E* Abdollahzadeh Sharghi, F Yadegari, L Davarpanah,

Background & objectives: Pharmaceutical wastewater contains high concentrations of organic matter, high salt and difficult biodegradability, so it must be treated before discharge to the environment. In this study, it is aimed to evaluate the treatment of pharmaceutical wastewater (methadone feedstock and neutralized capecitabine) using chemical and biological methods. Methods: The laboratory ...

2013
S. Kanmani

The treatment of bleach effluent from pulp and paper Industry for COD, colour and AOX removal was investigated using Ultra violet/Hydrogen peroxide process photocatalysed by Titanium dioxide. The Ultra violet / Titanium dioxide process was able to remove 48% and 37% of COD and colour. The Ultra violet / Hydrogen peroxide process was able to remove 52% and 59% of COD and colour. The combined pro...

Journal: :تحقیقات نظام سلامت 0
نعمت اله جعفرزاده حقیقی فرد استاد، مرکز تحقیقات فن آوری های زیست محیطی و گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران سیده مریم موسوی دانشجوی کارشناسی ارشد، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران مریم امیدی نسب دانشجوی کارشناسی ارشد، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران سهند جرفی استادیار، مرکز تحقیقات فن آوری های زیست محیطی و گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، ایران

background : the sequencing batch reactor (sbr) is one of the most widely used systems in sewage treatment because of the simplicity of the process, flexibility of operation in the removal of nutrients, and the ability to be used in different scales. the aim of this study was to evaluate the efficiency of the sbr in the removal of organic matter (nitrogen and phosphorus) from synthetic wastewat...

2016
Aifeng Qiu Qiang Cai Yuan Zhao Yingqing Guo Liqian Zhao

Landfill leachate is composed of a complex composition with strong biological toxicity. The combined treatment process of coagulation and sedimentation, anaerobics, electrolysis, and aerobics was set up to treat landfill leachate. This paper explores the effect of different operational parameters of coagulation and sedimentation tanks and electrolytic cells, while investigating the combined pro...

2017
M. Zielińska A. Cydzik-Kwiatkowska K. Bułkowska K. Bernat I. Wojnowska-Baryła

This study investigated the use of ceramic membranes to remove total suspended solids (TSS), organics (expressed by chemical oxygen demand, COD), and bisphenol A (BPA) via microfiltration (MF, pore size 0.45 μm) and ultrafiltration (UF, cutoff 150 kDa) in post-treatment of effluents from aerobic granular sludge reactors (GSBRs). The efficiency of removal of COD, BPA, and TSS in MF was similar t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید