نتایج جستجو برای: comparable images and resolution recovery reconstruction

تعداد نتایج: 16948152  

Bahareh Shalchian Hamid Soltanian-Zadeh Hossein Rajabi,

Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...

Journal: :Digital Signal Processing 2015
Salih Ugur Orhan Arikan Ali Cafer Gürbüz

a r t i c l e i n f o a b s t r a c t Synthetic Aperture Radar (SAR) provides high resolution images of terrain and target reflectivity. SAR systems are indispensable in many remote sensing applications. Phase errors due to uncompensated platform motion degrade resolution in reconstructed images. A multitude of autofocusing techniques has been proposed to estimate and correct phase errors in SA...

2010
Jae Sung Lee

The continuing efforts of investigators to achieve the best physical and clinical performances from PET (positron emission tomography) and related hybrid cameras (PET/CT and PET/MRI) have led to remarkable technical advances in hardware and software. Time of flight (TOF) information measurement, which has been enabled thanks to the invention of fast, heavy crystals and advances in fast light de...

2012
Kamaljit Chowdhary Jan S. Hesthaven Edward G. Walsh

In many imaging applications, such as functional Magnetic Resonance Imaging (fMRI), full, uniformlysampled Cartesian Fourier (frequency space) measurements are acquired to reconstruct an image. In order to reduce scan time and increase temporal resolution for fMRI studies, one would like to accurately reconstruct these images from the smallest possible set of Fourier measurements. The emergence...

2009
Radim Tyleček

In this paper we propose a pipeline for accurate 3D reconstruction from multiple images that deals with some of the possible sources of inaccuracy present in the input data. Namely, we address the problem of inaccurate camera calibration by including a method [1] adjusting the camera parameters in a global structure-and-motion problem which is solved with a depth map representation that is suit...

E. Raeisi, H. Rajabi, S.M.R. Aghamiri,

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

2007
Ryszard Stasinski

Abstract : The MRI reconstruction based on super−resolution back−projection algorithm is presented in the paper. It is shown that the approach improves MRI spatial resolution in cases when PROPELLER sequences are used. The PROPELLER MRI method collects data in rectangular strips rotated around the origin of the k−space. Inter−strip patient motion is the premise for the use of super−resolution t...

2013
Osama A. Omer

An important part of any computed tomography (CT) system is the reconstruction method, which transforms the measured data into images. Reconstruction methods for CT can be either analytical or iterative. The analytical methods can be exact, by exact projector inversion, or non-exact based on Back projection (BP). The BP methods are attractive because of thier simplicity and low computational co...

Journal: :Optics express 2017
Yunlong Meng Wei Lin Chenglin Li Shih-Chi Chen

We present a new two-snapshot structured light illumination (SLI) reconstruction algorithm for fast image acquisition. The new algorithm, which only requires two mutually π phase-shifted raw structured images, is implemented on a custom-built temporal focusing fluorescence microscope (TFFM) to enhance its axial resolution via a digital micromirror device (DMD). First, the orientation of the mod...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید