نتایج جستجو برای: diode calibration

تعداد نتایج: 76854  

2004
Chao-Te Li Derek Kubo Chih-Chiang Han Chung-Cheng Chen Ming-Tang Chen Chun-Hsien Lien Huei Wang Ray-Ming Wei Chia-Hsiang Yang Tzi-Dar Chiueh Jeffrey Peterson Michael Kesteven Warwick Wilson

A wideband correlator system with a bandwidth of 16 GHz or more is required for Array for Microwave Background Anisotropy (AMiBA) to achieve the sensitivity of 10μK in one hour of observation. Double-balanced diode mixers were used as multipliers in 4-lag correlator modules. Several wideband modules were developed for IF signal distribution between receivers and correlators. Correlator outputs ...

Journal: :Lab on a chip 2012
Siegfried W Kettlitz Sebastian Valouch Wiebke Sittel Uli Lemmer

Detection of fluorescence particles is a key method of flow cytometry. We evaluate the performance of a design for a microfluidic fluorescence particle detection device. Due to the planar design with low layer thicknesses, we avoid optical components such as lenses or dichroic mirrors and substitute them with a shadow mask and colored film filters. A commercially available LED is used as the li...

2017
Rocio B. Dominguez Miguel A. Orozco Giovanny Chávez Alfredo Márquez-Lucero

Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the de...

2016
P. X. Pham A. Kourmatzis A. R. Masri

Backlight imaging is a standard experimental technique used for the measurement of liquid fragment size and velocity in multiphase flows. When used with appropriate microscope lenses, quantitative information on the spray structure can be attained, including measurement of non-spherical objects. A critical issue resides in the nature of the measurement which is line integrated from a single vie...

Journal: :Journal of microscopy 2006
A D Elder J H Frank J Swartling X Dai C F Kaminski

High brightness light emitting diodes are an inexpensive and versatile light source for wide-field frequency-domain fluorescence lifetime imaging microscopy. In this paper a full calibration of an LED based fluorescence lifetime imaging microscopy system is presented for the first time. A radio-frequency generator was used for simultaneous modulation of light emitting diode (LED) intensity and ...

2006
Janusz Pienkowski

Diode lasers are becoming increasingly important in length metrology. We demonstrate construction of a simple single-frequency diode laser 632,8 nm, used as a frequency standard in the laser interferometers. We present two different systems applied for frequency stabilization of diode laser . For diode laser used as the secondary standard, the system stabilizes diode temperature, the frequency ...

Journal: :journal of lasers in medical sciences 0
ehsan azma nassimeh safavi laser application in medical sciences research center, shahid beheshti university of medical sciences, tehran, iran

introduction: diode laser with wavelengths ranging from 810 to 980 nm in a continuous or pulsed mode was used as a possible instrument for soft tissue surgery in the oral cavity. discussion: diode laser is one of laser systems in which photons are produced by electric current with wavelengths of 810, 940 and 980nm. the application of diode laser in soft tissue oral surgery has been evaluated fr...

Journal: :Microscopy research and technique 2015
Hongtao Chen Gerhard Holst Enrico Gratton

Widefield frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) is a fast and accurate method to measure the fluorescence lifetime of entire images. However, the complexity and high costs involved in construction of such a system limit the extensive use of this technique. PCO AG recently released the first luminescence lifetime imaging camera based on a high frequency modulated CM...

2016
Emrys G. Hall Allen F. Jordan Dale F. Hurst Samuel J. Oltmans Holger Vömel Benjamin Kühnreich Volker Ebert

The NOAA frost point hygrometer (FPH) is a balloon-borne instrument flown monthly at three sites to measure water vapor profiles up to 28 km. The FPH record from Boulder, Colorado, is the longest continuous stratospheric water vapor record. The instrument has an uncertainty in the stratosphere that is < 6 % and up to 12 % in the troposphere. A digital microcontroller version of the instrument i...

2016
Esin Akgul Kalkan Mehtap Sahiner Dilek Ulker Cakir Duygu Alpaslan Selehattin Yilmaz

Using high-performance liquid chromatography (HPLC) and 2,4-dinitrophenylhydrazine (2,4-DNPH) as a derivatizing reagent, an analytical method was developed for the quantitative determination of acetone in human blood. The determination was carried out at 365 nm using an ultraviolet-visible (UV-Vis) diode array detector (DAD). For acetone as its 2,4-dinitrophenylhydrazone derivative, a good sepa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید