نتایج جستجو برای: dose calculation

تعداد نتایج: 408802  

Journal: :Nuclear Technology and Radiation Protection 2006

Journal: :Japanese Journal of Radiological Technology 1991

Journal: :iranian journal of radiation research 0
m. yazdani department of physics, tarbiat moallem university of sabzevar, sabzevar, iran a.a. mowlavi department of physics, tarbiat moallem university of sabzevar, sabzevar, iran

background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...

2011
Tatsuhiko SATO Akira ENDO Koji NIITA

The fluence to effective-dose and organ-absorbed-dose conversion coefficients for charged pions and muons were calculated based on the instructions given in ICRP Publication 103. For the calculation, the particle motions in the ICRP/ICRU adult reference computational phantoms were simulated using the PHITS code for four idealized irradiation geometries as well as those closely representing the ...

2016
Robert L. Carver Conrad P. Sprunger Kenneth R. Hogstrom Richard A. Popple John A. Antolak

The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for...

2017
Nadine Spahr Philipp Schilling Smita Thoduka Nasreddin Abolmaali Andrea Schenk

BACKGROUND In the planning of selective internal radiation therapy (SIRT) for liver cancer treatment, one major aspect is to determine the prescribed activity and to estimate the resulting absorbed dose inside normal liver and tumor tissue. An optimized partition model for SIRT dosimetry based on arterial liver territories is proposed. This model is dedicated to characterize the variability of ...

2016
John P. Mullins Michael P. Grams Michael G. Herman Debra H. Brinkmann John A. Antolak

Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید