نتایج جستجو برای: dose calculation algorithm

تعداد نتایج: 1144675  

Danial Seifi Makrani Tayyeb Pourfallah

Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inh...

I.A. Kim, J.B. Chung, J.S. Kim, J.W. Lee, K.Y. Eom, M.J. Kim, S.W. Kang, T.S. Suh, Y.L. Kim,

Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a           6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...

Journal: :Medical physics 2012
J Jung W Cho J Lee D Kim M Kim T Suh

PURPOSE The aim of this study is to evaluate the accuracy the collapsed cone convolution (CCC) algorithm for dose calculation in a radiation treatment planning system (TPS). METHODS We modeled various photon beams for various setup conditions in a radiation treatment planning system (CorePLANTM, Seoul C&J, Korea). The beam models were generated at various set-up conditions such as open beam o...

Journal: :Radiation Oncology (London, England) 2006
Barbara Dobler Cornelia Walter Antje Knopf Daniella Fabri Rainer Loeschel Martin Polednik Frank Schneider Frederik Wenz Frank Lohr

BACKGROUND The aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment planning using accurate dose calculation algorithms. METHODS A 9-field conformal treatment plan was generated on an inhomogeneous phantom with lung mimics and a soft tissue equivalent insert, mimicking a lung...

Journal: :Medical physics 2003
Y Yang L Xing J G Li J Palta Y Chen Gary Luxton A Boyer

Independent verification of the MU settings and dose calculation of IMRT treatment plans is an important step in the IMRT quality assurance (QA) procedure. At present, the verification is mainly based on experimental measurements, which are time consuming and labor intensive. Although a few simplified algorithms have recently been proposed for the independent dose (or MU) calculation, head scat...

Journal: :iranian journal of medical physics 0
reza faghihi school of mechanical engineering, nuclear engineering department, shiraz university, shiraz, iran radiation research center, shiraz university, shiraz, iran

introduction after the publication of task group number 43 dose calculation formalism by the american association of physicists in medicine (aapm), this method has been known as the most common dose calculation method in brachytherapy treatment planning. in this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2003
Marco Schwarz Luc J Bos Ben J Mijnheer Joos V Lebesque Eugène M F Damen

BACKGROUND AND PURPOSE To assess the effect of differences in the calculation of the dose outside segment edges on the overall dose distribution and the optimisation process of intensity modulated radiation therapy (IMRT) treatment plans. PATIENTS AND METHODS Accuracy of dose calculations of two treatment planning systems (TPS1 and TPS2) was assessed, to ensure that they are both suitable for...

2005
Wendel Dean Renner Kevin Norton Timothy Holmes

A method to convert integrated electronic portal imaging device (EPID) images to fluence for the purpose of reconstructing the dose to a phantom is investigated here for simple open fields. Ultimately, the goal is to develop a method to reconstruct the dose to patients. The EPID images are transformed into incident intensity fluence by spatial filtering with a deconvolution kernel. The kernel u...

2016
Zhangkai J. Cheng Regina M. Bromley Brad Oborn Martin Carolan Jeremy T. Booth

The metallic fixations used in surgical procedures to support the spine mechani-cally usually consist of high-density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculatio...

2015
Yuji Nakaguchi Takeshi Ono Masato Maruyama Nozomu Nagasue Yoshinobu Shimohigashi Yudai Kai

In this study, we evaluated the performance of a three-dimensional (3D) dose verification system, COMPASS version 3, which has a dedicated beam models and dose calculation engine. It was possible to reconstruct the 3D dose distributions in patient anatomy based on the measured fluence using the MatriXX 2D array. The COMPASS system was compared with Monte Carlo simulation (MC), glass rod dosimet...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید