نتایج جستجو برای: dose volume histogram

تعداد نتایج: 619461  

Bahram Andalib Farimah Hajilooei Hassan Ali Nedaie, Hossein Hassani Kaveh Shirani Tak Abi Mahmood Samei Mansour Naderi Nooshin Banaee,

Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

2014
Hideharu Miura Norihisa Masai Ryoong-Jin Oh Hiroya Shiomi Kouichi Yamada Junichi Sasaki Muhammad Nauman Usmani Toshihiko Inoue

The purpose of this study was to compare the dose-volume statistics of stereotactic body radiotherapy (SBRT) for lung cancer between planning target volume (PTV): D95 and gross tumor volume (GTV): D99 dose prescriptions using Monte Carlo (MC) calculation. Plans for 183 patients treated between October 2010 and April 2013 were generated based on four-dimensional (4D) computed tomography (CT) und...

Journal: :American journal of clinical oncology 2006
Ajay K Bhatnagar Dwight E Heron Melvin Deutsch Edward Brandner Andrew Wu Shalom Kalnicki

PURPOSE To evaluate the relationship between the primary breast volume and dose received by the ipsilateral lung, heart (for left-breast cancers), and contralateral breast during primary breast irradiation using intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS Sixty-five patients with breast carcinoma were treated using 6-MV photons with IMRT technique using the Eclipse Pla...

Journal: :International journal of radiation oncology, biology, physics 2007
Nicolas Jansen Jean-Marie Deneufbourg Philippe Nickers

PURPOSE The aim of this study was to use permanent seed implants in the breast and describe our experience with 15 cases, using iodine seed implants as a tumor bed boost. METHODS AND MATERIALS Breasts were fixed with a thermoplastic sheet, a template bridge applied, the thorax scanned and the images rotated to be perpendicular to the implant axis. Skin, heart, and lung were delineated. A prep...

2015
Ji-Jin Yao Guan-Qun Zhou Li Lin Wang-Jian Zhang Ying-Lin Peng Lei Chen Ling-Long Tang Yan-Ping Mao Jun Ma Ying Sun

This study is to identify significant dosimetric parameters for ear disorders in nasopharyngeal carcinoma (NPC) patients treated with intensity modulated therapy only. Ninety-seven patients with NPC were retrospectively reviewed. Organs at risk (OARs) in the auditory apparatus were contoured. Dose-volume histogram parameters were generated for the Eustachian tube (ET), tympanic cavity (TC), mas...

2016
Ş. MORCOVESCU C. COSMA J. D. MORTON

The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target v...

2016
Juan Ren Wei Yuan Ruihua Wang Qiuping Wang Yi Li Chaofan Xue Yanli Yan Xiaowei Ma Li Tan Zi Liu

OBJECTIVE The purpose of this study was to comprehensively compare the 3-dimensional (3D) magnetic resonance imaging (MRI)-guided and conventional 2-dimensional (2D) point A-based intracavitary brachytherapy (BT) planning for cervical cancer with regard to target dose coverage and dosages to adjacent organs-at risk (OARs). METHODS A total of 79 patients with cervical cancer were enrolled to r...

2014
Joep Stroom Sandra Vieira Dalila Mateus Carlo Greco Antonella Fogliata Giorgia Nicolini Alessandro Clivio Eugenio Vanetti Luca Cozzi

BACKGROUND To appraise the robustness of VMAT dose distributions against uncertainties in the positioning of the patients when single fraction SABRT treatments are planned. METHODS A set of 18 patients (8 lung, 5 brain, 5 spinal or para-spinal) treated with VMAT in a single fraction of 24Gy were retrospectively analyzed. All approved plans were re-calculated by applying shifts to the isocentr...

2017
Tibor Major Csaba Polgár

In the last decades, treatment planning for multicatheter interstitial breast brachytherapy has evolved considerably from fluoroscopy-based 2D to anatomy-based 3D planning. To plan the right positions of the catheters, ultrasound or computed tomography (CT) imaging can be used, but the treatment plan is always based on postimplant CT images. With CT imaging, the 3D target volume can be defined ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید