نتایج جستجو برای: dosimetry verification

تعداد نتایج: 83031  

Journal: :Medical physics 2011
Daniel A Low Jean M Moran James F Dempsey Lei Dong Mark Oldham

Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The prop...

1999
Carita Aschan

The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: i) wide useful dose range, ii) small physical size, iii) no need for high voltage or cables, i.e. stand alone character, and iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be...

Journal: :Medical physics 2006
L N McDermott M Wendling B van Asselen J Stroom J J Sonke M van Herk B J Mijnheer

The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...

2017
Daniel Taussky Levon Igidbashian David Donath Dominic Béliveau-Nadeauv Renée X. Larouche Yanick Hervieux Guila Delouya

PURPOSE To analyze intraoperative (IO) dosimetry using transrectal ultrasound (TRUS), performed before and after prostate low-dose-rate brachytherapy (LDR-BT), and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30). MATERIAL AND METHODS A total of 236 patients underwent prostate LDR-BT using 125I that was performed with a three-dimensional TRUS-guided interactive ...

2012
C. M. M. Paschoal M. L. Sobrinho D. do N. Souza J. Antônio Filho L. A. P. Santos

Computed tomography (CT) dosimetry normally uses an ionization chamber 100 mm long to estimate the computed tomography dose index (CTDI), however some reports have already indicated that small devices could replace the long ion chamber to improve quality assurance procedures in CT dosimetry. This paper presents a novel dosimetry system based in a commercial phototransistor evaluated for CT dosi...

2016
Aiping Ding Bin Han Lei Wang Lei Xing

The aim in this study is to develop a generalized strategy for 3D dose verification of IMRT and VMAT planes using EPID transit images in combination with Monte Carlo (MC) simulations. An EPID-based dosimetric verification procedure was developed to convert EPID-measured transit images into 2D exit photon fluence by de-convoluting with the MC-simulated EPID response kernels. The present scatter ...

Journal: :European Journal of Nuclear Medicine and Molecular Imaging 2021

Abstract Purpose A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 ( 90 Y)-resin microspheres. Methods steering committee 23 international experts representing all participating specialties formulated SIRT Y-resin microspheres activity prescription and post-treatment dosimetry, ...

2014
Mohammad Bakhtiari Ashkan Parniani Fritz Lerma Shannon Reynolds James Jordan Alireza Sedaghat Mehrdad Sarfaraz James Rodgers

BACKGROUND Intensity modulated radiation therapy (IMRT) dosimetry verification is routinely conducted via integrated or individual field dosimetry using film or a matrix of detectors. Techniques and software systems are commercially available which use individual field dosimetry measurements as input into algorithms that estimate 3D patient dose distributions on CT scan derived target volumes a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید