نتایج جستجو برای: egsnrc

تعداد نتایج: 222  

Journal: :journal of medical signals and sensors 0
keivan jabbari hossein saberi anvar mohammad bagher tavakoli alireza amouheidari

background: the monte carlo method is the most accurate method for simulation of radiation therapy equipment. the linear accelerators are currently the most widely used machines in radiation therapy centers. methods: in this work, a monte carlo modelling of the siemens oncor linear accelerator in 6 mv and 18 mv beams was performed. the results of simulation were validated by measurements in wat...

Hajar Alipour, Kamal Hadad Reza Faghihi,

Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...

Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...

Journal: :Frontiers in Physics 2023

Purpose: The aim of this study is to investigate the depth-dependent detector response detailed thimble air-filled ionization chambers by calculating spectral charged particle fluence correction factors at different depths in water. Those will help understand, how varies and what kind influences disparate effects have on response. Methods: cema-approach can be used obtain fluence-based for vari...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

A. Amouheidari, M. Atarod, P. Shokrani,

Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...

Introdution: The aim of this study was to evaluate and benchmark EGSnrc code in the simulation of 18 MV photon beam produced by Siemens Oncor® linear accelerator. Methods: This study was conducted in a comparative and simulation based on experience method. The Beamnrc code was used to model the accelerator head and generate phase space files. The phase space files were obtained with the fo...

Gh. Geraily, Gh.R. Fallah Mohammadi1, N. Riyahi Alam, R. Paydar,

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

Journal: :iranian journal of radiation research 0
m. yarahmadi kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran kh. asnaashari department of radiotherapy , cancer institute, tehran university of medical sciences, tehran, iran o.a. sauer klinik und poliklinik für strahlentherapie, university of würzburg, josef-schneider-strasse 11, 97080 würzburg, germany

background: small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (imrt) and stereotactic radiosurgery (srs) treatments. accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. hence the ebt2 (external beam therapy) gafchromic film was used for dosimetry of sm...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید