Journal: :Talanta 2007
Kelly G Fernandes Ana Rita A Nogueira José A Gomes Neto Joaquim A Nóbrega

This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14molL(-1) HNO(3), 0....

Journal: :Clinical chemistry 1991
T P Moyer G V Mussmann D E Nixon

We evaluated the evacuated phlebotomy tube designed specifically for trace metal analysis by Sherwood Medical Co. Pools of human serum containing known concentrations of aluminum, arsenic, calcium, cadmium, copper, chromium, iron, lead, magnesium, manganese, mercury, selenium, and zinc were exposed to the tube and rubber stopper for defined periods ranging from 5 min to 24 h. Analysis for each ...

Journal: :Clinical chemistry 1989
H J Gitelman F R Alderman

An improved electrothermal atomic absorption spectrometric method for determination of aluminum in serum is described. An ammonium hydroxide/sulfuric acid diluent is used to control matrix effects from serum constituents. Because serum produces no apparent matrix effects with this diluent, one can accurately calibrate the procedure with aqueous standards.

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Shigehiro Kagaya Yusaku Hosomori Hidekazu Arai Kiyoshi Hasegawa

Cadmium ranging from 1 - 8 ng could be coprecipitated quantitatively with lanthanum phosphate at pH 5 - 6 from up to 200 mL of river water samples spiked with 5 microg of indium as an internal standard. Cadmium and indium coprecipitated were measured by using electrothermal atomic absorption spectrometry. The cadmium content in the original sample solution could be determined by internal standa...

Journal: :Clinical chemistry 1991
P C D'Haese L V Lamberts L Liang F L Van de Vyver M E De Broe

Direct measurement of lead and cadmium in blood and urine by electrothermal atomic absorption spectrometry with deuterium background correction (D2-AAS) is prone to severe matrix and spectral interferences. We overcame these effects by coating the L'vov platform with ammonium molybdate, reducing the atomization time, introducing a post-atomization cooling step, carefully selecting ashing and at...