نتایج جستجو برای: gafchromic film film dosimetry

تعداد نتایج: 98485  

Journal: :Physics in medicine and biology 2000
M J Butsont T Cheung P K Yu D Abbati G E Greenoak

Radiochromic film is tested for its broad-band response to ultraviolet (UV) B (290-320 nm) and A (320 nm400 nm), visible and infrared radiation produced by a solar simulator and examined for dosimetry in ultraviolet radiation. Results show that MD-55-2 radiochromic film in solar and fluorescent light sources responds almost exclusively to broad-band UVA radiation with negligible colouration fro...

2012
Masahiro Nakano Robin F. Hill May Whitaker Jung‐Ha Kim Zdenka Kuncic

The present study quantified surface doses on several rectangular phantom setups and on curved surface phantoms for a 6 MV photon field using the Attix parallel-plate chamber and Gafchromic EBT2 film. For the rectangular phantom setups, the surface doses on a homogenous water equivalent phantom and a water equivalent phantom with 60 mm thick lung equivalent material were measured. The measureme...

2016
Hideharu Miura Shuichi Ozawa Fumika Hosono Naoki Sumida Toshiya Okazue Kiyoshi Yamada Yasushi Nagata

Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-do...

2014
Mara Severgnini Mario de Denaro Marina Bortul Cristiana Vidali Aulo Beorchia

Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...

Journal: :Physics in medicine and biology 2002
Tsang Cheung Martin J Butson Peter K N Yu Peter Metcalfe

Photon beam dosimetry using Kodak extended dose range (EDR2) radiographic film can provide accurate and high spatial resolution information especially for areas such as IMRT dosimetry where a higher dose level (100-400 cGy) is often required to be delivered for verification. For such dosimetry checks, it may sometimes be useful to place the film in a tank filled with water during irradiation. T...

F. Ebrahimi Tazehmahalleh, H. Esmaily, H. Gholamhosseinian, M. Layegh, N. Ebrahimi Tazehmahalleh,

Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...

2016
Elsa Y. León Marroquin José A. Herrera González Miguel A. Camacho López José E. Villarreal Barajas Olivia A. García‐Garduño

Radiochromic film has become an important tool to verify dose distributions for intensity-modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the for...

Journal: :iranian journal of radiation research 0
f. ebrahimi tazehmahalleh department of medical physics, mashhad university of medical sciences, mashhad, iran h. gholamhosseinian radiotherapy center of emam reza hospital, mashhad, iran m. layegh radiotherapy center, omid hospital, mashhad, iran n. ebrahimi tazehmahalleh motahari clinic, khoy, azarbaijan, iran h. esmaily department of bio-statistics, mashhad university of medical sciences, mashhad, iran

background: the goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. materials and methods: the study was carried out using a nepton 10...

A.S. Meigooni, H. Ghafourian, H. Pourbeigi, M.H. Zahmatkesh, R.A. Koona,

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید