نتایج جستجو برای: gafchromic rtqa film
تعداد نتایج: 90984 فیلتر نتایج به سال:
The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calib...
In the present study, a series of experiments were performed to study collisions runaway electrons in Damavand tokamak by imaging hard x-ray radiations, as one secondary effects these electrons, using radiochromic films. For experiments, GAFCHROMIC™EBT2 dosimetry films selected due their high resolution capability. These instruments installed two strip and screen structures for one- two-dimensi...
Dose distribution verification for GYN brachytherapy using EBT Gafchromic film and TG-43 calculation
Purpose: This study investigated whether real-time variable shape tungsten rubber (STR) could be applied for nail radiation protection in total skin electron beam (TSEB) therapy. Methods: Simulated finger phantoms were made from syringes filled with physiological saline of volumes 5, 10, 20, and 30 ml (inner diameters 14.1, 17.0, 21.7, 25.3 mm, respectively). Gafchromic film was to the phantom,...
PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...
PURPOSE Bombarding high-Z material with x-ray radiation releases Auger electrons and Coster-Kronig electrons, along with deeper penetrating fluorescent x-rays and photoelectrons. The Auger and Coster-Kronig electron penetration distance is on the order of nanometers to micrometers in water or tissue, creating a large dose enhancement accompanied by a RBE greater than 1 at the cellular level. Th...
PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...