نتایج جستجو برای: implant stability

تعداد نتایج: 344005  

Journal: :Journal of Orthopaedic Surgery and Research 2009
Aldemar A Hegewald Sven Knecht Daniel Baumgartner Hans Gerber Michaela Endres Christian Kaps Edgar Stüssi Claudius Thomé

BACKGROUND Surgery for disc herniations can be complicated by two major problems: painful degeneration of the spinal segment and re-herniation. Therefore, we examined an absorbable poly-glycolic acid (PGA) biomaterial, which was lyophilized with hyaluronic acid (HA), for its utility to (a) re-establish spinal stability and to (b) seal annulus fibrosus defects. The biomechanical properties range...

2016
Choknapa Tirachaimongkol Peraphan Pothacharoen Peter A Reichart Pathawee Khongkhunthian

OBJECTIVES The purposes of this study were to examine the correlation between the stability of dental implants and bone formation markers during the healing period and to monitor the stability of dental implants using the resonance frequency analysis (RFA) method. The null hypothesis of the study is no correlation between the stability of dental implant and bone formation markers. METHODS The...

2017
Nicolas Grognard Gino Verleye Dimitrios Mavreas Bart Vande-Vannet

BACKGROUND The healing of xenograft augmentated intra-alveolar gaps following immediate implant placement (IMIP) after tooth extraction is likely to differ in time and density compared to the native bone part that directly contacts the implant. MATERIAL AND METHODS Secondary implant stability (SIS) data recorded 2-3 months following a late implant placement protocol (LIP) (n= 43) and 6-8 mont...

2016
Adrien Michel Romain Bosc Jean-Paul Meningaud Philippe Hernigou Guillaume Haiat

BACKGROUND The primary stability of the acetabular cup (AC) implant is an important determinant for the long term success of cementless hip surgery. However, it remains difficult to assess the AC implant stability due to the complex nature of the bone-implant interface. A compromise should be found when inserting the AC implant in order to obtain a sufficient implant stability without risking b...

Journal: :Journal of shoulder and elbow surgery 2012
Dave R Shukla James S Fitzsimmons Kai-Nan An Shawn W O'Driscoll

BACKGROUND Osteointegration of press-fit radial head implants is achieved by limiting micromotion between the stem and bone. Aspects of stem design that contribute to the enhancement of initial stability (ie, stem diameter and surface coating) have been investigated. The importance of total prosthesis length and level of the neck cut has not been examined. METHODS Cadaveric radii were implant...

Journal: :The International journal of oral & maxillofacial implants 2008
Pär-Olov Ostman Mats Hellman Lars Sennerby

PURPOSE The purpose of the present prospective clinical study was to evaluate the radiographic and clinical outcome of immediately loaded implants in the partial edentulous mandible over a 4-year follow-up period using a modified surgical protocol, primary implant stability criteria, and splinting for inclusion. MATERIALS AND METHODS Patients in need of implant treatment in the partial edenta...

2016
Julius Maminskas Algirdas Puisys Ritva Kuoppala Aune Raustia Gintaras Juodzbalys

OBJECTIVES To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. MATERIAL AND METHODS An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies o...

2015
Seung-Yun Shin Seung-Il Shin Seung-Beom Kye Seok-Woo Chang Jongrak Hong Jun-Young Paeng Seung-Min Yang

PURPOSE Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. METHODS Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no...

2017
Rik C. Nelissen Christine A. den Besten Emmanuel A. M. Mylanus Myrthe K. S. Hol

The objective of this study was to compare the stability, survival, and tolerability of 2 percutaneous osseointegrated titanium implants for bone conduction hearing: a 4.5-mm diameter implant (test) and a 3.75-mm diameter implant (control). Fifty-seven adult patients were included in this randomized controlled clinical trial. Sixty implants were allocated in a 2:1 (test–control) ratio. Follow-u...

Journal: :The International journal of oral & maxillofacial implants 2015
Jin Whan Lee Hai Bo Wen Suneel Battula Rama Akella Michael Collins Georgios E Romanos

PURPOSE This study evaluated the stability and histologic proof of osseoincorporation of Trabecular Metal (TM) dental implants, which feature a tantalum-based porous midsection. MATERIALS AND METHODS A total of 48 TM implants (test group) and Tapered Screw-Vent implants (control group) were immediately placed bilaterally into mandibular extraction sockets in dogs. Resonance frequency analysis...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید