background: electronic portal imaging devices (epids) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. a successful utilization of epids for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. in this study, two in-house phantoms were developed and analyzed for implementation in a qua...
background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose v...
background: palladium-103 (103pd) is a brachytherapy source for cancer treatment. the monte carlo codes are usually applied for dose distribution and effect of shieldings. monte carlo calculation of dose distribution in water phantom due to a med3633 103pd source is presented in this work. materials and methods: the dose distribution around the 103pd model med3633 located in the center of 30×30...
Objective: Different categories are available for estimating of radiation dose. Radioisotopes with the same energy and almost the same physical properties have similar effects. Monte Carlo technique is a computerized method based on mathematical simulation of physical processes. The main purpose of this study is to show that beta particles are not able to penetrate deep into the water. also dif...
The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiation therapy as an additional dose delivery check. In this study we have extended a method developed by A. Piermattei and colleagues in 2006 that made use of EPID transit images (acquired during treatment) to calculate dose in the isocenter point. The extension allows calculation of two-di...
The radiation doses received by individuals from radionuclides which enter the human body cannot be measured directly but must be inferred. In these calculations several measurable quantities (as the internal whole body burden or urine daily excretion) and quantities derived from models are employed. The Radiation Protection Quantities for internal dosimetry are in principle the same as for ext...
Purpose: In radiotherapy, the proper way to ensure that the dose delivered to a patient is correct and strongly agree with that simulated by his treatment plan currently requires a pre-treatment dosimetric verification. Although this procedure can be realised by using a combined detectorphantom system to monitor the patient plan dose delivered on a phantom, the quality of the entire treatment c...
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...
BACKGROUND The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD The phantom de...