ii PREFACE Part I of the present series described a study to evaluate radiation detection and imaging systems commonly found in hospitals to determine their suitability for rapidly scanning individuals for internal contamination, and to develop recommendations regarding their potential use (Anigstein et al. 2007a). That report described the measurement of count rates from single discrete radioa...
Introduction: The Sc is an important parameter to monitor unit (MU) calculation in radiation therapy procedure. The aim of this study is to measurement and comparison of head scatter factor (Sc) for 9MV photon beam using the build-up cap and a columnar mini-phantom. Materials and Methods: The measurements performed using a calibrated ion chamber (Scanditron...
Introduction: Due to nuclear interactions between the tissues and high-energy protons, the particles, including neutrons, positrons, and photons arise during proton therapy. This study aimed at investigating the dose distribution of proton and secondary particles, such as positrons, neutrons, and photons using the Monte Carlo method. Material and Methods:<...
We modified the Imaging Performance Assessment of CT scanners (ImPACT) to evaluate the organ doses and the effective dose based on the International Commission on Radiological Protection (ICRP) Publication 110 reference male/female phantom with the Aquilion ONE ViSION Edition scanner. To select the new CT scanner, the measurement results of the CTDI100,c and CTDI100,p for the 160 (head) and the...
We describe a phantom for simultaneous electroencephalography (EEG) and near-infrared imaging which consists of a solid, optically turbid and electrically conducting interface enclosing a tissue-mimicking aqueous scattering solution. The interface provides an electrical contact impedance comparable to that of the human scalp while the phantom as a whole has optical properties and electrical con...
Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...
A neonatal head phantom, comprising of an ellipsoidal geometry and including a circular aperture for simulating the fontanel was designed and fabricated, in order to allow an objective assessment of thermal rise in tissues during trans-cranial ultrasonic scanning of pre-term neonates. The precise position of a series of thermocouples was determined on the basis of finite-element analysis, which...
spect detects γ-rays from administered radiopharmaceutical within the patient body. γ-rays pass through different tissues before reaching detectors and are attenuated. attenuation can cause artifacts; therefore different methods are used to minimize attenuation effects. in our study efficacy of chang method was evaluated for attenuation purpose, using a custom made heart phantom. due to differe...