نتایج جستجو برای: modified transient current limiter
تعداد نتایج: 1142971 فیلتر نتایج به سال:
As one of the solution of the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects t...
In this paper, we develop bound-preserving modified exponential Runge-Kutta (RK) discontinuous Galerkin (DG) schemes to solve scalar conservation laws with stiff source terms by extending the idea in Zhang and Shu [39]. Exponential strong stability preserving (SSP) high order time discretizations are constructed and then modified to overcome the stiffness and preserve the bound of the numerical...
This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...
Experiments are underway on the Alcator C Tokamak with over 1 MW of RF power injected into the plasma at a frequency of 4.6 GHz to study both heating and current drive effects. During these studies, impurity generation from limiter structures has been observed. The RF induced impurity influx is a strongly nonlinear function of net injected power. For Prf < 500 kW, only small effects are seen. A...
A fault current limiter (FCL) may be applied to assist the low-voltage ride-through (LVRT) of a doubly fed induction generator (DFIG). FCLs with fixed impedance, lack flexibility adjust their impedance adapt different LVRT scenarios. The direct switch-in and -out fixed-impedance FCL yields transient electromagnetic oscillations in DFIG, which need addressed. In this paper, variable-impedance is...
In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...
The light absorption coefficient of hydrogenated nanocrystalline silicon has been engineered to have a Gaussian distribution by means of absorption modification using a femtosecond laser. The absorption-modified sample exhibits a significant absorption enhancement of up to ∼700%, and the strong absorption does not depend on the incident light. We propose a model responsible for this interesting...
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
This paper considers the problem of the detection of a binary phase-modulated carrier which has been transmitted along with noise through a hard-limiting repeater, corrupted by additional noise, and demodulated by cross correlation and sampling at the receiver. Three equivalent expressions are obtained for the error probability of the receiver output. Two of these expressions take the form of a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید