Wakefields excited in the small aperture collimators may damage the beam. As pointed out by K. Bane and P. Morton the wakefields can be reduced considerably by tapering the steps and using the “step+taper” collimator geometry. The optimisation of this kind of geometry for TTF 2 collimators with different apertures is carried out in the paper. For the optimal geometries the nonlinear near-wall w...
Activation products have been identified by in situ gamma spectroscopy at the isocenter of a medical linear accelerators shortly after termination of a high energy photon beam irradiation with 15 x 15 cm field size. Spectra have been recorded either with open or with closed collimator. Whilst some activation products disappear from the spectrum with closed collimator or exhibit reduced count ra...
An a irradiation device is described that utilises a commercially available disc-shaped americium-241 source of 8 cm diameter. The a particles traverse a moving collimator and the source is rotated to reduce the influence of source inhomogeneities. Source, collimator and a shutter disc are mounted in a container which is flushed with helium to reduce energy losses of the a particles before reac...
Efforts are being made to develop a new type of CT system that can scan volumes over a large range within a short time with thin slice images. One of the most promising approaches is the combination of helical scanning with multi-slice CT, which involves several detector arrays stacked in the z direction. However, the algorithm for image reconstruction remains one of the biggest problems in mul...
The main objective of this project is to implement the multiple fan beam projection technique using optical fibre sensors with the aim to achieve a high data acquisition rate. Multiple fan beam projection technique here is defined as allowing more than one emitter to transmit light at the same time using the switch-mode fan beam method. For the thirty-two pairs of sensors used, the 2-projection...
Abstract: We present a neural network approach for tomographic imaging problem using interpolation methods and fan-beam projections. This approach uses a partially connected neural network especially assembled for solving tomographic reconstruction with no need of training. We extended the calculations to perform reconstruction with interpolation and to allow tomography of fan-beam geometry. Th...
For the production of a clinical 15 MV photon beam, the design of accelerator head assembly has been optimized using Monte Carlo based FLUKA code. The accelerator head assembly consists of etarget, flattening filter, primary collimator and an adjustable rectangular secondary collimator. Accelerators used for medical radiation therapy generate continuous energy gamma rays called bremsstrahlung r...
A cone-beam image reconstruction algorithm using spherical harmonic expansions is proposed. The reconstruction algorithm is in the form of a summation of inner products of two discrete arrays of spherical harmonic expansion coefficients at each cone-beam point of acquisition. This form is different from the common filtered backprojection algorithm and the direct Fourier reconstruction algorithm...