نتایج جستجو برای: non linear loads
تعداد نتایج: 1737193 فیلتر نتایج به سال:
In this work a new control strategy for simulation of three phase power filter for power quality improvement is used .This filter consists of shunt passive LC power filter and series active filter, with nonlinear and linear loads and also with variation in the source impedance. A new control method based on dual formulation of instantaneous reactive power vectorial theory is applied by consider...
The estimation of harmonic components of power voltage signals is one of the measurements prescribed by the power quality (PQ) standards (IEC 61000-4-30, 2008). In general, the harmonic components originate from non-linear elements connected to the power system such as non-linear loads (e.g., switched-mode power supplies) or transformers. An example of a distorted voltage measured in an office ...
This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...
Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in transformer parts. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these p...
Industrial and domestic equipments use non-linear electronic components. As examples of these nonlinear loads: rectifiers, inverters, choppers or in a general manner, all equipments using the electronic switches and the junctions with semiconductors. This creates non sinusoidal electrical currents which will be injected in the electrical supply network. These non sinusoidal currents present oth...
It is demonstrated that supra-linear (greater than linear) speedup is possible in processing distributed divisible computational loads where computation time is a nonlinear function of load size. This result is radically different from the traditional distributed processing of computational loads with linear processing complexity appearing in over 50 journal papers.
A comprehensive wind-tunnel test program on both a 65o delta an 80o/65o double delta wing model has been recently completed. The program included static and dynamic force tests. A brief description of the various experiments is presented, as well as results that demonstrate the value of the previously proposed "hypersurface" representation of aerodynamic loads in the non-linear and unsteady reg...
the creep behavior of basalt fiber reinforced epoxy (bfre) and glass fiber reinforced epoxy (gfre) composites was studied through tensile testing at high temperature. to study the effect of reinforcing epoxy, the micro glass powder (mgp) was added at various volume percentage into the epoxy resin in bfre composites. the initial strain for all the specimens were evaluated and compared with each ...
harmonics have become an important issue in modern power systems. the widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. this paper employs an extended harmonic domain (ehd) based framework for dynamic analysis of long term analysis over voltages during the tra...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید