Dong Wu Zhao Kameshwar Poolla

TOWARDS A COMPLETE PLASMA DIAGNOSTIC SYSTEM by Dong Wu Zhao Doctor of Philosophy in Engineering-Electrical Engineering & Computer Sciences University of California at Berkeley Professor Costas J. Spanos, Chair We have set up a plasma diagnostic system with three sources of signals, OES, RF, and machine signals. CF2 OES lines 275 nm and 321 nm are found to be better than any other signals for po...

2014
Cristina Gonzalez-Gago Petr Smid Thomas Hofmann Cornel Venzago Volker Hoffmann Wolfgang Gruner

The performance of glow discharge optical emission spectroscopy and mass spectrometry for oxygen determination is investigated using a set of new conductive samples containing oxygen in the percent range in three different matrices (Al, Mg, and Cu) prepared by a sintering process. The sputtering rate corrected calibrations obtained at standard conditions for the 4 mm anode (700 V, 20 mA) in GD-...

Journal: :Physical chemistry chemical physics : PCCP 2015
Yu-Lin Kuo Yu-Ming Su Hung-Lung Chou

This study describes the use of a composite nitrate salt solution as a precursor to synthesize CeO2 and Gd2O3-doped CeO2 (GDC) nanoparticles (NPs) using an atmospheric pressure plasma jet (APPJ). The microstructures of CeO2 and GDC NPs were found to be cubical and spherical shaped nanocrystallites with average particle sizes of 10.5 and 6.7 nm, respectively. Reactive oxygen species, detected by...

Journal: :Physical review letters 2005
Yu A Litvinov T J Bürvenich H Geissel Yu N Novikov Z Patyk C Scheidenberger F Attallah G Audi K Beckert F Bosch M Falch B Franzke M Hausmann Th Kerscher O Klepper H-J Kluge C Kozhuharov K E G Löbner D G Madland J A Maruhn G Münzenberg F Nolden T Radon M Steck S Typel H Wollnik

The FRS-ESR facility at GSI provides unique conditions for precision measurements of large areas on the nuclear mass surface in a single experiment. Values for masses of 604 neutron-deficient nuclides (30 < or = Z < or = 92) were obtained with a typical uncertainty of 30 microu. The masses of 114 nuclides were determined for the first time. The odd-even staggering (OES) of nuclear masses was sy...

2016
Mariusz Ślachciński

A pressurized continuous flow system using electromagnetic induction heating technique has been developed for the determination of trace and minor element content in biological samples by microwave induced plasma-optical emission spectrometry (MIP-OES). The system allows the continuous solubilization of samples at an optimized temperature of 120 °C and pressure of 3.5 bar in 40 min. A system wa...

2003
Marcellé Archer Robert I. McCrindle Egmont R. Rohwer

Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used to measure the concentrations of cobalt, tantalum, titanium, vanadium and chromium in solutions of tungsten carbide. The main advantage of the method described here lies in the speed, convenience and effectiveness of the dissolution procedure. Aliquots of powdered tungsten carbide were dissolved in a solution of 5% aqua...

Journal: :Analytical chemistry 2006
Lee L Yu Therese A Butler Gregory C Turk

The certification of Standard Reference Material (SRM is a registered trademark of NIST) 3103a As Spectrometric Solution is based on the gravimetric preparation value that is verified by inductively coupled plasma optical emission spectrometry (ICP-OES) measurements. A disagreement between the gravimetric and the spectrometric values for a batch of As calibration solutions led to the discovery ...

Journal: :Metallomics : integrated biometal science 2010
Chethaka L Kahakachchi Dennis A Moore

The gadolinium species present in a rat kidney following intravenous administration of a gadolinium-based magnetic resonance contrast agent (Optimark™, Gadoversetamide injection) to a rat was examined in the present study. The major gadolinium species in the supernatant of the rat kidney tissue extracts was determined by reversed-phase liquid chromatography with online inductively coupled plasm...

2005
JACK M. FEIN

Regional oxidative metabolism was studied in vivo. Oxygen availability was monitored from polarographic electrodes in frontal cortical and subcortical tissue. The rate of oxygen extraction in these regions was estimated at frequencies of up to 3 measurements per minute. Transient ischemia of the frontal regions was induced and the resultant decay in the oxygen trace was analyzed kinetically. Th...

2005
Fabiana S. Felix Jaim Lichtig Luciana B.O. dos Santos Jorge C. Masini

A concentração de Cd, Pb e Ni em material particulado atmosférico coletado no ambiente de trabalho de três fundições localizadas no município de Loanda, Paraná, Brasil, foram determinadas por voltametria de onda quadrada e ICP OES. Os resultados mostram que os trabalhadores estão sendo sistematicamente expostos a concentrações de Cd e Pb que são significativamente maiores do que o Limite de Con...