نتایج جستجو برای: peak detector

تعداد نتایج: 198135  

Journal: :iranian journal of basic medical sciences 0
shahnaz gauhar department of pharmaceutics, faculty of pharmacy, university of karachi, karachi, pakistan syed ayub ali department of pharmaceutics, faculty of pharmacy, university of karachi, karachi, pakistan harris shoaib department of pharmaceutics, faculty of pharmacy, university of karachi, karachi, pakistan syed baqir shyum naqvi department of pharmaceutics, faculty of pharmacy, university of karachi, karachi, pakistan iyad naeem muhammad department of pharmaceutics, faculty of pharmacy, university of karachi, karachi, pakistan

objective(s) developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (rp-hplc) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. materials and methods a shim-pack clc-ods column and a mobile phase constituting acetonitrile: 0.025 m phosphoric acid solution (13:87 v/v, ph ...

Journal: :the modares journal of electrical engineering 2007
mohammad reza taban mohammad reza aref

in this paper a new algorithm is presented for coherent radar detection of targets, when distribution of the interference (clutter and noise) is non-gaussian. the neyman-pearson criterion is used for optimal detection and several successive received samples from a radar range cell are used for detection in the same cell. on the basis of recent empirical evidences, the interference distribution ...

2005
MARTIN FISCHER KLAUS ALEXANDER

Doppler sonography of 29 extracranial carotid arteries was performed twice within three days or less. Angiography revealed stenoses with from 10 to 95% diameter reduction in 25 internal carotid arteries whereas four vessels were found to be normal. The systolic peak frequency of the internal carotid artery read from the Doppler spectrum (n = 29) could be reproduced very well. This was shown by ...

Journal: :IEICE Transactions 2007
Ching-Yuan Yang Jung-Mao Lin

In this letter, a 1.25-Gb/s 0.18-μm CMOS half-rate burstmode clock and data recovery (CDR) circuit is presented. The CDR contains a fast-locking clock recovery circuit (CRC) using a realigned oscillation technique to recover the desired clock. To reduce the power dissipation, the CRC uses a two-stage ring structure and a current-reused concept to merge with an edge detector. The recovered clock...

2013
Mashhour M. Ghanem Saleh A. Abu-Lafi Hussein O. Hallak

A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 m...

2009
Christopher G. Worley

Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if the detector has adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicates spectral interpretation. Thi...

2003
Hongyu Jiang Jacquelyn C. Yanch Ruth E. Shefer Jeffrey A. Coderre

Boron Neutron Capture Synovectomy (BNCS) is a novel application of the B(n,α) reaction for potential treatment of rheumatoid arthritis. During BNCS clinical trials, real-time knowledge of boron dose delivered to the synovium is necessary so that the remaining irradiation time can be determined. A 478 keV photon is emitted following 94% of boron neutron capture reactions, and detection of 478 ke...

2005
Robert C. McFarland

sult in interpolated efficiencies differing by as much as 6% when using different curve-fitting functions in the 700-keV to 900-keV region? Second, since the coincidencefree standard only covered the energy range of 59.5 keY to 1115.5 keV,how much uncertainty would be introduced by extrapolating the curve fits to higher energy where there were no experimental points? Third, what effect would on...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2014
Po-Ting Chen Hsiao-Ping Chen Chia-Hung Hung Shau-Chun Wang

Static light-scattering (LS) detection can determine the molecular weight (MW) of polymers eluted with size-exclusion chromatography (SEC) without using any standards when the differential refraction index (RI) of solutes are obtained. On the other hand, the noisy chromatographic signal peak acquired using a static LS detector often causes difficulty in peak-width recognition. This disadvantage...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید