نتایج جستجو برای: pedicle

تعداد نتایج: 5739  

2014
Weitao Li Yangyang Liu Zhiyu Qian

BACKGROUND There is a high probability of accidental perforation of the vertebral pedicle wall in pedicle screw insertion surgery. A pedicle screw (PS) measurement device with an optical probe has been reported to send out a warning signal before the PS tip breaking the vertebral pedicle wall. METHODS In this study, we explored the detection depth of optical probe in this measurement device, ...

Journal: :Journal of orthopaedic surgery 2014
Chun Ee Tan Margaret Woon Man Fok Keith Dip Kei Luk Kenneth Man Chee Cheung

PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end pla...

2016
Qiang-Hua Zhang Hai-Dong Li Ji-Kang Min

OBJECTIVE To investigate how the anatomy of variant atlas vertebra impacts on the strategy used to place pedicle screws used to treat atlantoaxial instability. METHODS The study enrolled patients with cervical instability who had a posterior arch pedicle height <3.5 mm at the anchor point, a vertebral artery groove height <3.5 mm, or both. Pedicle screws were fitted according to the anatomy o...

2010
Robert Green Watkins Akash Gupta

OBJECTIVE To determine if image-guided spine surgery is cost effective. METHODS A prospective case series of the first 100 patients undergoing thoracolumbar pedicle screw instrumentation under image-guidance was compared to a retrospective control group of the last 100 patients who underwent screw placement prior to the use of image-guidance. The image-guidance system was NaviVision (Vector V...

2014
Mohamed M Mohi Eldin

STUDY DESIGN All parameters were measured manually and with a computed tomography (CT) scanner. For the manual measurements, a Vernier scale instrument was used. PURPOSE This study evaluates quantitatively pedicles of middle and lower cervical spine (C3 to C7) and to evaluate the possibilities of using these structures as anchors in posterior cervical fusion. OVERVIEW OF LITERATURE Pedicle ...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2015
Dursun O Karakoyun Mustafa Özkaya Volkan C Okutan Ali Dalgıç Deniz Belen Teyfik Demir

Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to ...

2013
WEIJIE HUANG TAO LUO

The present study aimed to discuss the method and effect of posterior internal fixation of thoracolumbar fractures strengthened by the vertical stress pedicle screw fixation of fractured vertebrae. Patients with single thoracolumbar fractures were examined retrospectively. Fourteen patients (group A) had been treated with vertical stress pedicle screw fixation of a fractured vertebra and sixtee...

Journal: :Annali italiani di chirurgia 2007
Igor Papalia Francesco Stagno d'Alcontres Michele Rosario Colonna Ali M Mojallal Jean-Louis Foyatier

AIM OF THE STUDY The superior pedicle mammaplasty is a technique frequently employed in the treatment of breast ptosis, associated or not with hypertrophy of the gland, followed by satisfactory results. This technique is normally not indicated in severe breast ptosis (pendulous breast) because of the excessive length of the pedicle supplying nipple-areola-complex (NAC), with the risk of ischemi...

Journal: :Clinical anatomy 2014
Rodolfo Morales-Avalos Jorge Leyva-Villegas Gabriela Sánchez-Mejorada Marcela Cárdenas-Serna Félix Vílchez-Cavazos Angel Martínez-Ponce De León Guillermo Elizondo-Riojas Jorge Martínez-García Oscar De La Garza-Castro Rodrigo Elizondo-Omaña Santos Guzmán-López

Transpedicular spinal fusion is the most commonly used fixation technique for the surgical treatment of vertebral disorders. However, the instrumentation of the thoracic spine using this technique continues to be controversial. The objective of the present study was to determine the morphometric characteristics of the thoracic pedicle and to establish how these characteristics vary with gender ...

Journal: :Neurosurgery 2001
J B West J M Fitzpatrick S A Toms C R Maurer R J Maciunas

OBJECTIVE To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. METHODS We consider two clinical situations: cranial neurosurgery and pedicle screw placement. For cranial neurosurgery, we apply theoretical results concerning TRE prediction, which we have previously derived and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید