نتایج جستجو برای: phantom dosimetry pelvis
تعداد نتایج: 39383 فیلتر نتایج به سال:
We have investigated the feasibility of using a set of multiple MOSFETs in conjunction with the mobile MOSFET wireless dosimetry system, to perform a comprehensive and efficient quality assurance (QA) of IMRT plans. Anatomy specific MOSFET configurations incorporating 5 MOSFETs have been developed for a specially designed IMRT dosimetry phantom. Kilovoltage cone beam computed tomography (kV CBC...
objective: different categories are available for estimating of radiation dose. radioisotopes with the same energy and almost the same physical properties have similar effects. monte carlo technique is a computerized method based on mathematical simulation of physical processes. the main purpose of this study is to show that beta particles are not able to penetrate deep into the water. also dif...
INTRODUCTION Monte Carlo (MC) methods have become the "gold standard" for assessing dose distribution, organ doses and effective dose associated with the exposure, both external and internal, of humans to ionizing radiation. Powerful and sophisticated tools for simulation of radiation transport (for example, MCNP, EGS4) are now widely available. However, these codes are designed for general-pur...
The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 ...
This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning sys...
We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the r...
BACKGROUND Femoroacetabular impingement (FAI) is increasingly recognized as a potential cause of hip osteoarthritis. A system capable of pre-operatively simulating hip range of motion (ROM) by given surface models from either healthy or FAI diseased bone is desirable. METHODS An impingement detection system using bounding sphere hierarchies was first developed. Both precision and accuracy of ...
The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...
OBJECTIVE To investigate if software simulation is practical for quantifying random error (RE) in phantom dosimetry. MATERIALS AND METHODS We applied software error simulation to an existing dosimetry study. The specifications and the measurement values of this study were brought into the software (R version 3.0.2) together with the algorithm of the calculation of the effective dose (E). Four...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید