نتایج جستجو برای: potentiometric titration

تعداد نتایج: 15740  

Ali Benvidi, Hamid Reza Zare, Mehdi Elahizadeh Rasoul Vafazadeh

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

Journal: :journal of the iranian chemical research 0
ali benvidi department of chemistry, faculty of science, yazd university, yazd, iran mehdi elahizadeh department of chemistry, faculty of science, yazd university, yazd, iran hamid reza zare, department of chemistry, faculty of science, yazd university, yazd, iran rasoul vafazadeh department of chemistry, faculty of science, yazd university, yazd, iran

an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...

Journal: :iranian chemical communication 2014
rasoul pourtaghavi talemi sajjad bakhtiari nabi javadi morteza vatanparast

in the present study, we investigate the potentiometric behavior of cu2+ carbon paste electrodes based on two mercapto compounds 2-ethylmino-5-mercapto-1,3,4-thiadiazole (eamt) and 2-acetylamino-5-mercapto-1,3,4-thiadiazole (aamt) self-assembled on gold nano-paricle (gnp) as ionophore. then, the results obtained from the modified electrodes are compared. the self-assembled ionophores exhibit a ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Khalil Farhadi Ramin Maleki

A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be u...

2015
J. C. B. Fernandes

This paper presents an alternative strategy for manufacturing solid-state reference electrodes based on particles of graphite/silver/silver chloride synthesized by electroless deposition of metallic silver and silver chloride on graphite powder. Two kinds of reference electrodes were manufactured by mixing these particles with epoxy resin and hardener: quasi-reference and all-solid-state contai...

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

Journal: :Jordan journal of chemistry 2021

A simple manual micro-titration method is proposed for the potentiometric and conductometric titration of 200 to 800 µL liquid samples. The sample be titrated dispensed into chamber; bottom section a plastic test tube that glued center small stirring magnet. After inserting sensing probe tip titrant delivery chamber, chamber-stirring magnet assembly spun at low speed using conventional magnetic...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2005
Golamreza Khayatian Hadi Rezatabar Abdollah Salimi

A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10...

2006
T. Andjelkovic A. Bojic

A direct potentiometric titration method was applied to commercial and soil humic acids in order to determine their carboxyl and phenol group concentrations and apparent and intrinsic pK. In that context, acid-base properties of humic acids are interpreted by selective blocking of carboxylic and phenolic groups by esterification and acetylation. Differences in underivatized and derivatized HA’s...

2003
F. LEE RODKEY ERIC G. BALL

There have been many investigations of the oxidation-reduction potential of the cytochrome c system. Some of the results are concordant, though none at the time this work was undertaken included a complete potentiometric titration of the system over a range of pH values. Potentials have been reported for the system at varying pH values, usually within a narrow range bordering on the physiologic...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید