نتایج جستجو برای: power factor correction

تعداد نتایج: 1455146  

2001
Kamon Jirasereeamornkul Y. Roungraungpalangkul Kosin Chamnongthai

The flyback-flyback single stage converter operated in DCM+DCM is easy to control bus voltage, but it hard to control stress of switch. We propose a new converter having low voltage stress on its switch. The flyback converter is simplified into buck-boost form. Then the PFC flyback transformer is replaced by an inductor The switch of both PFC and DC/DC stages are merged, and a diode is used to ...

2014
R. Abd Allah

In modern digital protection and control systems, an alienation technique has recently become the workhorse of quantitative research and analysis. In this paper, an alienation technique is developed for calculations of original power factor on-line, active and compensation reactive powers and determination of the required number of capacitor banks to get the desired power factor. Alienation coe...

2013
P. Kripakaran J. Sathishkumar R. Gopi Krishna

Harmonic pollution and low power factor in power systems caused by power converters have been a great concern. To overcome these problems several converter topologies and control schemes have been proposed in recent years. This paper is proposed to study the control techniques for such converters to improve the Power Factor (PF) and reduce total harmonic distortion (THD) in the input current wi...

1999
J. M. Bourgeois

The new European Norms EN 60555 and the international standard IEC555 will impose a limit on the harmonic content of the input current of mains supplied equipment. In practice this will require the addition of a Power Factor Corrector (PFC) at the input of many types of mains operated electronic equipment, for example electronic lamp ballasts, TV power supplies and motor drives. A correctly des...

Journal: :Circuits and Systems 2011
Renbo Xu Hongjian Li Yongzhi Li Changqian Zhang

A new type of high power LED drivers is proposed by adopting an improved two-stages non-isolated configuration. In order to improve power factor and achieve accurate average current control under universal input voltages ranging from 100 Vrms to 240 Vrms, the power factor correction and average current mode control methods operating in continuous current conduction mode are designed and impleme...

2001
Vlad Grigore

The equipment connected to an electricity distribution network usually needs some kind of power conditioning, typically rectification, which produces a nonsinusoidal line current due to the nonlinear input characteristic. With the steadily increasing use of such equipment, line current harmonics have become a significant problem. Their adverse effects on the power system are well recognized. Th...

2016
Krishna Kumar Bhargav Vijay Kumar Garg

© 2016, IRJET | Impact Factor value: 4.45 | ISO 9001:2008 Certified Journal | Page 959 Analysis of power factor correction of PV-Grid interconnected system Krishna Kumar Bhargav1, Vijay Kumar Garg2 1PG Scholar, Electrical Engineering, UIET Kurukshetra University, Haryana, INDIA 2Assistant professor, Electrical Engineering, Kurukshetra University, Haryana, INDIA [email protected], 2 vkgarg2...

2010
Eka FIRMANSYAH Satoshi TOMIOKA Seiya ABE Masahito SHOYAMA Tamotsu NINOMIYA

This paper explains about basic working principles, implementation problems, and experimental results of a new power factor correction (PFC) topology. In this proposed topology, a totem-pole boost PFC circuit that works under interleaved critical-conduction-mode (CRM) condition is presented. The circuit is developed towards high efficiency, high performance, lowcost, simple control scheme, and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید