نتایج جستجو برای: varian accelerator

تعداد نتایج: 18438  

Background: External beam radiation therapy is often administered to patients implanted with silicone gel breast prosthesis. The aim of this study was to investigate the influence of silicone gel breast prosthesis on photon dose distributions. In the event of recurrence, the oncologist may be forced to irradiate through the prosthetic device. To quantify the dose enhancement or reduction below ...

H.A. Nedaie, Kh. Asnaashari, M. Allahverdi, M. Yarahmadi, O.A. Sauer,

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

2016
Narges Miri Peter Keller Benjamin J. Zwan Peter Greer

We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...

A. Shams, H. Shahbazian, M.A. Behrooz, M.J. Tahmasebi Birgani,

Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...

Journal: :iranian journal of radiation research 0
gh. geraily department of medical physics, tehran university of medical science, tehran, iran m. mirzapour department of electronic, east tehran branch, islamic azad university, tehran, iran s.r. mahdavi department of medical physics, tehran university of medical science, tehran, iran m. allahverdi department of medical physics, tehran university of medical science, tehran, iran a. mostaar department of biomedical engineering and medical physics, shahid beheshti university of medical science, tehran, iran m. masoudifar department of radiation oncology, mahak hospital, tehran, iran

background: physical wedges are still widely used as beam modifiers in external beam radiotherapy. however the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. the aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...

Journal: :iranian journal of radiation research 0
m. yarahmadi kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran kh. asnaashari department of radiotherapy , cancer institute, tehran university of medical sciences, tehran, iran o.a. sauer klinik und poliklinik für strahlentherapie, university of würzburg, josef-schneider-strasse 11, 97080 würzburg, germany

background: small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (imrt) and stereotactic radiosurgery (srs) treatments. accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. hence the ebt2 (external beam therapy) gafchromic film was used for dosimetry of sm...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :the modares journal of electrical engineering 2007
abdolreza sepyani ehsanolah kabir farid behazin

many of the video processing algorithms cannot be implemented in real time on general computers, due to their computational complexity. for an efficient implementation, a custom hardware that can be reconfigured for the algorithm, is used. in this paper a new acceleration hardware based on fpga elements is proposed. this hardware can be adapted with the processing algorithm through fpga design ...

Journal: :International journal of radiation research 2021

Background: Our aim was to analyze the effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer by using kilovoltage cone-beam CT (CBCT). Materials and Methods: In this study, we used a Varian IX linear accelerator system perform CBCT scans 30 patients before radiotherapy. Subsequently, image matched with planned CT, left right (LR), top bottom (SI), front back (A...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید