Chromium carbide – nickel chromium powder Cr3C2-25wt.NiCr was plasma sprayed by a water-stabilized system WSP®. A series of experiments with variable feeding distance was carried out. Basic characterization of coatings was done by XRD, SEM and light microscopy plus image analysis. Microhardness was measured on polished cross sections. The main focus of investigation was on resistances against w...
The importance of wear particle characterization for orthopaedic implants has long been established in the hip and knee arthroplasty literature. With the increasing use of motion preservation implants in the spine, the characterization of wear debris, particularly metallic nature, is gaining importance. An accurate morphological analysis of wear particles provides for both a complete characteri...
Wear particle-induced osteolysis is a major cause of aseptic loosening, which is one of the most common reasons for total hip arthroplasty (THA) failure. Previous studies have shown that the synovial fibroblasts present in the periprosthetic membrane are important targets of wear debris during osteolysis. However, the interaction mechanisms between the wear debris and fibroblasts remain largely...
STUDY DESIGN In vitro wear testing of the Bryan Cervical Disc prosthesis was performed in a cervical spine simulator. The biologic response was assessed in chimpanzee and goat animal models. OBJECTIVE Determine the wear characteristics of the Bryan disc. SUMMARY OF BACKGROUND DATA Large joint arthroplasties fail most commonly by wear and consequent formation of particulate material, which i...
It is hypothesized that structured sliding-surfaces improve the lubrication condition by forming an oil sump on sliding surface, redistributing oil, and trapping wear debris. For these reasons, have been used as a friction reduction method for long time. In this work, effects of microstructure laid cylinder liner internal combustion engine twin-land control ring (TLOCR) piston skirt were invest...
Aseptic loosening of prosthetic implants remains a serious orthopaedic problem and the greatest limitation to total joint arthroplasty. Central to the etiology of aseptic loosening is periprosthetic osteolysis at the bone-implant interface, which is caused by wear debris-induced inflammation. This inflammation produces the critical osteoclast differentiation factor RANKL, which directly stimula...
We examined the correlation of wear effects with dielectric properties of carbon nanofibers (CNFs; untreated and organosilane-treated)-reinforced high-density polyethylene (HDPE) composites. Wear testing for the nanocomposites over up to 120 h was carried out, and then, dielectric permittivity and dielectric loss factor of the polymer composites with the increased wear time were studied. Scanni...
Relative motion at interacting implant surfaces generates wear debris over time leading to periprosthetic osteolysis and device failure. Factors related to implant design, patient habitus and surgical approach will impact the generation of wear debris and influence the clinical longevity of artificial spinal disc devices. Further, surgeons play an important role in selecting the appropriate imp...