We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used ...
PURPOSE To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. METHODS The standard method (AAPM's TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 c...
background: pet/ct imaging using [18f]-fdg is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. essential consideration must be taken for radiation staff due to high gamma radiation in pet/ct and cyclotron center. the aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in pet/ct an...
background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...
This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantag...
Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are presented and special attention is paid to the calibration of the R and K type de...
A single dose comparison of a combination of fenoterol and ipratropium aerosols in bronchial asthma.
Nine patients with reversible obstructive airways disease were studied to compare the bronchodilator response to a combination of fenoterol and ipratropium aerosols with two dose levels of fenoterol alone. Using a double-blind, cross-over, single dose regime, 200 micrograms fenoterol hydrobromide and 80 micrograms ipratropium bromide was compared to 400 micrograms fenoterol + placebo, and to 20...
Figure shows the absolute change in the Dmean for the anal sphincter (left y-axis) and relative change in the V64Gy for the rectal wall (right y-axis) expressed as a function of the relative increase in the homogeneity index HI of the dose distribution in the PTV. Conclusions: By increasing the inhomogeneity of the targeted dose to the PTV in prostate RT plans the dose delivered to the rectal w...
The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calib...