نتایج جستجو برای: auxiliary collimator
تعداد نتایج: 24268 فیلتر نتایج به سال:
BACKGROUND Post-therapy SPECT/CT imaging of 90Y microspheres delivered to hepatic malignancies is difficult, owing to the continuous, high-energy Bremsstrahlung spectrum emitted by 90Y. This study aimed to evaluate the utility of a commercially available software package (HybridRecon, Hermes Medical Solutions AB) which incorporates full Monte Carlo collimator modelling. Analysis of image qualit...
performing fast and accurate methods for modeling the electrical machines has been the subject of several studies and many authors proposed different procedures to attain this aim. beside the accuracy, the speed of the method is of great concern. on the other hand, the capability of the method to be changed according to the need is another important issue. finite element method provides relativ...
BACKGROUND Image-based measurement of absorbed dose of Ra-223 dichloride may be useful in predicting therapeutic outcome in patients with castration-resistant prostate cancer (CRPC). In general, SPECT has been found to be more accurate than planar imaging in terms of lesion-based analysis. The aims of this study were to assess the feasibility and clinical usefulness of Ra-223 SPECT. The energy ...
Introduction: Accurate calculation of equal square field size is important in radiation therapy and A factor, in the Vadash formula must be determine by considering collimator exchange effect. Therefore, the purpose of this study was to determine the best A factor, for calculation of equal square field size in treatment planning Materials and Methods: A new...
We find the conditions for optimal collimator location by the method of “Lagrange undetermined multipliers”. We give a ‘global’ explanation for the advantage of tune splitting on betatron collimation in terms of the envelope of all possible optimal collimator positions. We make analytic calculations of the maximum amplitude of surviving particles for elliptic and jaw-type collimators at a varie...
We present results of investigations of the clinical significance of variations in the value of the 4-mm-collimator output factor, OF(4/18). Changes in treatment volume, dose-volume histograms (DVHs), and isodose distributions were studied, by varying OF(4/18) up to 20%. The variations were performed on a sample of clinical patient treatment plans for which the 4 mm collimator was used. Althoug...
The angular deflection of a 28.5 GeV electron beam passing off-axis between the jaws of a collimator, generating a transverse wakefield, were measured in End Station A (ESA) at SLAC. In total, fifteen different configurations of collimator geometry and material were tested: some were chosen for compatibility with previous measurements while others served to study the effect of geometry and tape...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید