نتایج جستجو برای: bio impedance analysis

تعداد نتایج: 2895096  

2015
Sylvia Kalainy Ryan Reid Kailash Jindal Neesh Pannu Branko Braam

BACKGROUND Achievement of normal volume status is crucial in hemodialysis (HD), since both volume expansion and volume contraction have been associated with adverse outcome and events. OBJECTIVES The objectives of this study are to assess the prevalence of fluid volume expansion and depletion and to identify the best clinical parameter or set of parameters that can predict fluid volume expans...

Journal: :journal of physical & theoretical chemistry 2014
hossein tajabadipour mehdi shahidi nima karachi

vanillin is an interesting corrosion inhibitor because of its safe use and high solubility inwater. the effect of vanillin on the corrosion inhibition of carbon steel in 1.0 mhydrochloric acid solution has been studied using potentiodynamic polarization,electrochemical impedance spectroscopy (eis) and electrochemical noise (en) techniques.the effect of temperature on the rate of corrosion in th...

2017
Silviu Dovancescu Pierpaolo Pellicori Thato Mabote Azam Torabi Andrew L. Clark John G.F. Cleland

AIMS Pharmacological therapies for heart failure (HF) aim to improve congestion, symptoms, and prognosis. Failing to take medication is a potential cause of worsening HF. Characterizing the effects of short-term medication omission could inform the development of better technologies and strategies to detect and interpret the reasons for worsening HF. We examined the effect of planned HF medicat...

2012
Yixian Wang Zunzhong Ye Yibin Ying

The development of a rapid, sensitive, specific method for the foodborne pathogenic bacteria detection is of great importance to ensure food safety and security. In recent years impedimetric biosensors which integrate biological recognition technology and impedance have gained widespread application in the field of bacteria detection. This paper presents an overview on the progress and applicat...

Journal: :Biosensors & bioelectronics 2012
Shabnam Siddiqui Zhenting Dai Courtney J Stavis Hongjun Zeng Nicolaie Moldovan Robert J Hamers John A Carlisle Prabhu U Arumugam

It is well recognized that label-free biosensors are the only class of sensors that can rapidly detect antigens in real-time and provide remote environmental monitoring and point-of-care diagnosis that is low-cost, specific, and sensitive. Electrical impedance spectroscopy (EIS) based label-free biosensors have been used to detect a wide variety of antigens including bacteria, viruses, DNA, and...

2014
Rebecca Kuriyan Tinku Thomas Sangeetha Ashok Jayakumar J Anura V. Kurpad

BACKGROUND & OBJECTIVES Many methods are available for measuring body fat of an individual, each having its own advantages and limitations. The primary objective of the present study was to validate body fat estimates from individual methods using the 4-compartment (4C) model as reference. The second objective was to obtain estimates of hydration of fat free mass (FFM) using the 4C model. MET...

Journal: :Macromolecular Materials and Engineering 2021

Bio-based epoxy resins are attracting widespread interest in the field of polymer thermosets as environmentally friendly building block. In present study, feasibility applying UV-curable epoxidized vegetable oils (EVOs) anti-corrosion coating is investigated. Rheological characterization EVOs carried out, and their viscosity-shear relationship evaluated. The cationic UV-curing successfully give...

Journal: :IEEE Sensors Journal 2021

Electrochemical Impedance Spectroscopy (EIS) is a powerful measurement technique used by scientists and engineers to characterize understand the interfacial behavior of liquid-solid interfaces. Such investigations are important in numerous applications fields research, including electrochemical synthesis deposition materials, such as metals conducting polymers, corrosion protection analysis, in...

2015
CHENG-HSIN CHUANG Cheng-Hsin Chuang Ting-Fe Wu Cheng-Ho Chen Kai-Chieh Chang Jing-Wei Ju Yao-Wei Huang Yuan-Chu Yu Da-Huei Lee Ting-Feng Wu Shih-Min Chen Hsun-Pei Wu

Point-of-care testing (POCT), or bedside testing is defined as medical testing at or near the site of patient care. In order to approach POCT, a miniaturization system consists of microfluidics chip, bio-recognition probes and electrically sensing element for providing enough information on clinical diagnosis. As the result, multidisciplinary researches and integrations are crucial for developi...

2014
J. Claudel

This paper presents a micro-biosensor based on Electrical Bio-Impedance Spectroscopy (EBIS), applied to blood cells characterization and diagnosis. This sensor uses microfluidic flow, coupled to EBIS system to perform cell by cell measurements at high flow rate, up to several hundred cells per second. Two devices were realized with different materials, SU_8 resin and polydimethylsyloxane PDMS t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید