نتایج جستجو برای: central venous pressure

تعداد نتایج: 911194  

2005
J. EDWIN WOOD JULIUS LITTER ROBERT W. WILKINS

V ENOCONSTRICTION has been suggested as an explanation for a variety of observations made on animals and humans suffering from cardiac decompensation.'-5 We have used the method described by Litter and coworkers for measuring peripheral venous distensibility' to study this aspect of congestive heart failure in man. The method measures the increment of limb volume occurring in response to a know...

2003
J. Skinner J. Brennan

s of papers 31 133 Venous Blood Pressure in Broilers During Acute Inhalation of 5% Carbon Dioxide, and During Unilateral Pulmonary Artery Occlusion. R. F. Wideman, Jr.*, P. Maynard, and W. G. Bottje, . We evaluated the hypothesis that venous congestion (increased venous volume) and venous hypertension (increased venous pressure), may arise when the right ventricle must elevate the pulmonary art...

Journal: :Circulation 1969
P A Mohr D O Monson C Owczarski W C Shoemaker

Sequential measurements of cardiac output, intravascular pressures, blood gases, pH, blood volume, and oxygen consumption were made in normal subjects and patients in shock before, during, and after infusions of dextran-40. In eight normal subjects the responses were: increased central venous pressure, increased cardiac index, decreased peripheral resistance, and decreased hemoglobin concentrat...

2011
Yong Seon Choi Ji Young Park Young Lan Kwak Jong Wha Lee

We present a case of inadvertent arterial insertion of a central venous catheter, identified during a pericardiectomy procedure after observing abrupt changes in pressure waveform and confirmed via arterial blood gas analysis and transesophageal echocardiography. Central venous pressure measurement was initially 20 mmHg in supine, and then elevated to 30-40 mmHg in right lateral decubitus, pres...

2005
J. EDWIN

V ENOCONSTRICTION has been suggested as an explanation for a variety of observations made on animals and humans suffering from cardiac decompensation.'-5 We have used the method described by Litter and coworkers for measuring peripheral venous distensibility' to study this aspect of congestive heart failure in man. The method measures the increment of limb volume occurring in response to a know...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشگاه پیام نور استان تهران - دانشکده اقتصاد و علوم اجتماعی 1390

abstract deviation or in other words committing a crime is literally a social problem. this research that was conducted in 1389 and 1390 has tried to investigate the causes of crimes committed by young male inmates qazvin central prison and effective variables on their tendency to deviation. accordingly after collecting theoretical framework and offering theoretical model including both hirsch...

Journal: :Critical care medicine 2004
Andrew Rhodes E David Bennett

OBJECTIVE In 2003, critical care and infectious disease experts representing 11 international organizations developed management guidelines for early goal-directed therapy that would be of practical use for the bedside clinician, under the auspices of the Surviving Sepsis Campaign, an international effort to increase awareness and improve outcome in severe sepsis. DESIGN The process included ...

Journal: :nephro-urology monthly 0
yoshiaki nishite department of biomedical engineering, faculty of biology-oriented science and technology, kinki university, wakayama, japan; department of biomedical engineering, faculty of biology-oriented science and technology, kinki university, wakayama, japan. tel: +81-736773888, fax: +81-736774754 shingo takesawa department of medical engineering, kyushu university of health and welfare clinical engineering, nobeoka, japan

conclusions thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. results the results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accident...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید