نتایج جستجو برای: chromic dosimeter presage

تعداد نتایج: 3817  

Journal: :iranian journal of radiation research 0
n.n.a razak school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. rahman 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia s. kandaiya 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia i.s. mustafa 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. mahmoud 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia n.z. yahaya school of distance education, university sains malaysia, 18000, pulau pinang, malaysia

background: an effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. materials and methods: the magat gel dosimeter formulations that used different compositions of methacrylic acid (maa) and gelatin were extensively investigated in the present study according to the r2–dose response and r2–dose sensitivity. the irradiation of magat gel was per...

2012
H. R. Moore W. Blum

The conductivity and density of chromic acid solutions were determined (<*r concentrations up to 10 molar (1,000 g/1 of Cr03 ). The density is practically a linear function of concentration. The conductivity increases to a maximum at about 5 molar and then decreases. CONTENTS Page

2000
H. Stadtmann J. Fellinger K. J. Velbeck C. Schmitzer J. E. Rotunda E. Michler

A new extremity TLD system has been developed and tested that provides for user convenience and automated processing while meeting various accreditation requirements. The design is a result of successful collaboration among organisational entities in different countries and included research centres, users, and the manufacturer. The primary consideration was to meet the needs of the medical mar...

Journal: :Journal of physics. Conference series 2013
M Niebanck T Juang J Newton J Adamovics Z Wang M Oldham

Stereotactic radiosurgery has become a widely used technique to treat solid tumors and secondary metastases of the brain. Multiple targets can be simultaneously treated with a single isocenter in order to reduce the set-up time to improve patient comfort and workflow. In this study, a 5-arc multifocal RapidArc treatment was delivered to multiple PRESAGE® dosimeters in order to explore the repea...

2014
M Costa C McErlean J Adamovics S J Doran

High Intensity Focused ultrasound (HIFU) is a non-invasive cancer therapy that makes use of the mainly thermal effects of ultrasound to destroy tissue. In order to achieve reliable treatment planning, it is necessary to characterise the ultrasound source (transducer) and to understand how the wave propagates in tissue and the energy deposition in the focal region. This novel exploratory study i...

Journal: :Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology 2005
A V Parisi M G Kimlin D J Turnbull J Macaranas

The research reported in this paper on the changes in absorbance and the calibration of a proposed UVA (320-400 nm) dosimeter have established the phenothiazine-mylar combination as a potential UVA dosimeter for population studies of UVA exposures. The change in optical absorbance at 370 nm was employed to quantify the UVA exposures. This change starts to saturate at a change in absorbance of a...

Journal: :Langmuir : the ACS journal of surfaces and colloids 2011
Justyn Jaworski Keisuke Yokoyama Chris Zueger Woo-Jae Chung Seung-Wuk Lee Arun Majumdar

Because of their unique optical and stimuli-response properties, polydiacetylene-based platforms have been explored as an alternative to complex mechanical and electrical sensing systems. We linked chromic responsive polydiacetylene (PDA) onto a peptide-based molecular recognition element for trinitrotoluene (TNT) molecules in order to provide a system capable of responding to the presence of a...

Journal: :تولیدات دامی 0
مهناز صالحی مربی پژوهشی، بخش فرآوری تولیدات دامی، مؤسسه تحقیقات علوم دامی کشور، کرج ژاله میرعبدالباقی مربی پژوهشی، بخش تحقیقات تغذیه، مؤسسه تحقیقات علوم دامی کشور، کرج محمد علی کمالی سروستانی استادیار پژوهشی، معاونت پژوهشی سازمان آموزش و تحقیقات کشاوررزی، تهران

the study was consequently investigated effect of different tanning methods on apparent density, thickness, tensile strength and also extension percentage in three different tanning (chromic, alum and vegetable) of grown part of ostrich skins (n = 15; 12 to 14 months). average apparent density and thickness of leathers were 0.7 ± 0.0gr/cm2 and 1.7 ± 0.1 mm, respectively. the breaking load, tens...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید