نتایج جستجو برای: coefficient of variance
تعداد نتایج: 21171462 فیلتر نتایج به سال:
Three-dimensional (3D) body scanners are increasingly used to derive 1D body dimensions from 3D whole body scans for instance, as input for clothing grading systems to make made-to-measure clothing or for width and depth dimensions of a seated workstation. In this study, the precision of the scanner-derived 1D dimensions from the CAESAR survey, a multinational anthropometric survey, was investi...
The probability of a rare event is usually estimated directly as the number of times the event occurs divided by the total sample size. Unfortunately, the precision of this estimate is low. For typical sample sizes of N , 100 in ecological studies, the coefficient of variation (CV) of this estimate of the probability of a rare event can exceed 300%. Sample sizes on the order of 103–104 observat...
The purpose of this study was to assess both short-term reliability and long-term stability of anthropometric and physical performance measures in highly-trained young soccer players in relation to age and maturation. Data were collected on 80 players from an academy (U13-U18, pre- (n = 14), circum- (n = 32) and post- (n = 34) estimated peak height velocity, PHV). For the reliability analysis, ...
The purpose of this study was to determine the reliability of short-term power output, heart rate (HR) response during and after a treadmill test, and time to complete a 25-m dash in healthy preschool children. Thirty-two 3- to 5-year-old boys and girls completed two sessions approximately one week apart. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated...
The objective of this work was to implement a motion-detection algorithm on a commercial real-time functional magnetic resonance imaging (fMRI) processing package for neurosurgical planning applications. A real-time motion detection module was implemented on a commercial real-time processing package. Simulated functional data sets with introduced translational, in-plane rotational, and through-...
CONTEXT Although reliability is a population-specific property, few studies have investigated the measurement error associated with force-platform parameters in athletic populations. OBJECTIVE To investigate the skill-related differences between athletes and nonathletes in reliability of center-of-pressure (COP) summary measures under eyes-open (EO) and eyes-closed (EC) conditions. DESIGN T...
Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.
Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing software settings. We analyzed best quality MBW measurements performed with an u...
A rigorous understanding of brain dynamics and function requires a conceptual bridge between multiple levels of organization, including neural spiking and network-level population activity. Mounting evidence suggests that neural networks of cerebral cortex operate at a critical regime, which is defined as a transition point between two phases of short lasting and chaotic activity. However, desp...
PURPOSE To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany). METHODS The right eyes of 79 healthy subjects were prospectively...
The purposes of this study were: (i) to determine the test-retest reliability of isokinetic ankle dorsiflexor strength measurements in young healthy adults using the Biodex dynamometer, and (ii) to examine several statistical measures for the interpretation of reliability. Thirty men and women (mean age 23 +/- 3 years) performed three maximal concentric contractions at 30 degrees/s, 60 degrees/...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید