Jafar Fatahi Asl Marziyeh Tahmasbi Mohammad Javad Tahmasebi Birgani Mohammad.Ali Behrooz Nahid Chegeni Raziye Fayazi

Introduction: Accurate calculation of equal square field size is important in radiation therapy and A factor, in the Vadash formula must be determine by considering collimator exchange effect. Therefore, the purpose of this study was to determine the best A factor, for calculation of equal square field size in treatment planning   Materials and Methods: A new...

2003
S. Koscielniak

We find the conditions for optimal collimator location by the method of “Lagrange undetermined multipliers”. We give a ‘global’ explanation for the advantage of tune splitting on betatron collimation in terms of the envelope of all possible optimal collimator positions. We make analytic calculations of the maximum amplitude of surviving particles for elliptic and jaw-type collimators at a varie...

2003
John P. Gibbons Dimitris Mihailidis Curtis Worthington Hassaan Alkhatib Raleigh Boulware Robert Clark Burke Dial William Neglia

We present results of investigations of the clinical significance of variations in the value of the 4-mm-collimator output factor, OF(4/18). Changes in treatment volume, dose-volume histograms (DVHs), and isodose distributions were studied, by varying OF(4/18) up to 20%. The variations were performed on a sample of clinical patient treatment plans for which the 4 mm collimator was used. Althoug...

2008
J. L. Fernandez-Hernando

The angular deflection of a 28.5 GeV electron beam passing off-axis between the jaws of a collimator, generating a transverse wakefield, were measured in End Station A (ESA) at SLAC. In total, fifteen different configurations of collimator geometry and material were tested: some were chosen for compatibility with previous measurements while others served to study the effect of geometry and tape...

2016
Ming-Hao Liu Cosimo Gorini Klaus Richter

An electron collimator composed of a point-like source and a parabolic pn junction is proposed as a generator of highly focused electron beams in graphene. The collimator is based on negative refraction and Klein collimation, which are unique to pseudo-relativistic Dirac materials. The electron beams generated by the lensing apparatus can be steered by a weak magnetic field without losing colli...

Journal: :journal of biomedical physics and engineering 0
sh banari bahnamiri

background: obtaining high quality images in single photon emission tomography (spect) device  is the most important goal in nuclear medicine. because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. one of the most important factors in sp...

Jamal Amiri

Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...

2008
B. Leonard Holman Robert E. Zimmerman Louis V. Bifolck Rudi D. Neirinckx

Tantalum-178 is a short-lived radionuclide (Tm = 9.3 min.) and emits primarily 56to 64-keV characteristic x-rays. We have determined the imaging characteristics with this radionuclide and a large-field-of-view Anger camera. With a pinhole collimator, good spatial resolution is possible with Ta-178, although the image quality is superior with Tc-99m under comparable conditions. Spatial resolutio...

Journal: :International Journal of Mathematics and Mathematical Sciences 2010