نتایج جستجو برای: density and attenuation
تعداد نتایج: 16878946 فیلتر نتایج به سال:
Skeletal muscle contains intramyocellular lipid droplets within the cytoplasm of myocytes as well as intermuscular adipocytes. These depots exhibit physiological and pathological variation which has been revealed with the advent of diagnostic imaging approaches: magnetic resonance (MR) imaging, MR spectroscopy and computed tomography (CT). CT uses computer-processed X-rays and is now being appl...
PURPOSE With the development of RT treatment planning systems that use the relationship between CT number and Electron Density (ED), rather than the Linear Attenuation Coefficient (LAC) of a given material, a number of authors have pointed out the divergence between the linearity of CT numbers vs. LAC in the diagnostic range compared to the relationship between the CT number and ED. This paper ...
Engineering the density of carbon nanotube (CNT) forest microstructures is vital to applications such as electrical interconnects, micro-contact probes, and thermal interface materials. For CNT forests on centimeter-scale substrates, weight and volume can be used to calculate density. However, this is not suitable for smaller samples, including individual microstructures, and moreover does not ...
Introduction: With the extensive application of radiation sources and radioactive materials in various fields, the study of attenuation and absorption of X-rays and gamma-rays in several materials has become an essential and interesting field of research. Glass materials are possible alternatives of concretes for radiation-shielding materials. Materials and Methods:...
Cataract is very frequent disease of human eye and the diagnosis of this disease is not difficult. However, it is important to describe it quantitatively, but it is difficult using only the slit lamp. Ultrasound examinations are widely used in ophthalmology. Piezoelectric crystals generate ultrasound waves of 5–50 MHz. Short pulses of 2 to 3 cycles are sent from transducer into the eye. These p...
We generalize the Poisson equation to attenuated Newtonian potentials. If the attenuation is at least exponential, the equation provides a local mapping between the density and its potential. We use this to derive several density functionals for the short-range self-interaction energy.
Development of borehole geophysics has recently focused on reservoir characterization. Within this effort, extensive full waveform acoustic surveys have demonstrated a correlation between the occurance of open fractures and attenuation of Stoneley waves. A relationship is obtained here between fracture permeability and attenuation of Stoneley waves, on the basis of a physical mechanism. This me...
Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...
Introduction: Protecting the vital organs in radiation therapy is one of the most important issues. Cerrobend alloy, the most common material used as the shield, is melted several times and used for different patients. In this study changes in attenuation coefficient of cerrobend due to melting was investigated. Materials and Methods: In melting furnace, ...
The ultrasound attenuation coefficient and dispersion from 0-70 MHz in whole human blood and its components (red blood cells and plasma) at 37°C is reported. The measurements are made using a fixed path substitution technique that exploits optical mechanisms for the generation and detection of ultrasound. This allows the measurements to cover a broad frequency range with a single source and rec...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید