2017
M. Ismail M. Afzal M. Nadeem A. M. Rana S. Amjad S. A. Buzdar

*Corresponding author: Muhammad Ismail, Department of Physics, Bahauddin Zakariya University, Multan, 60800-Pakistan. E-mail: [email protected] Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being use...

2011
Ryosuke Kohno Kenji Hotta Taeko Matsuura Kana Matsubara Shie Nishioka Teiji Nishio Mitsuhiko Kawashima Takashi Ogino

We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correctin...

2004
Shigeru Yokoyama Peter L. Roberson Dale W. Litzenberg Jean M. Moran Benedick A. Fraass

The more complex delivery techniques required for implementation of intensity-modulated radiotherapy (IMRT) based on inverse planning optimization have changed the relationship between dose at depth and dose at buildup regions near the surface. Surface buildup dose is dependent on electron contamination primarily from the unblocked view of the flattening filter and secondarily from air and coll...

Journal: :archives of breast cancer 0
mahdi aghili department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran parisa seifi department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran farshid farhan department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran ahmad reza sebzari department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran ehsan mohamadi department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran vahid vaezzadeh department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran

background: the axillary and supraclavicular nodal volume treatment results in improvement of local control and survival after breast conserving surgery (bcs) or modified radical mastectomy (mrm). studies on the depth of these nodes have questioned the consistent use of standard fields for all patients. this study was done to assess the dose delivery to these lymph nodes with conventional treat...

2013
Mohamad Javad Tahmasebi Birgani Nahid Chegeni Shole Arvandi Sasan Razmjoo Ghalaee Mansoor Zabihzadeh Davood Khezerloo

Nowadays, in most radiotherapy departments, the commercial treatment planning systems (TPS) used to calculate dose distributions needs to be verified; therefore, quick, easy-to-use, and low-cost dose distribution algorithms are desirable to test and verify the performance of the TPS. In this paper, we put forth an analytical method to calculate the phantom scatter contribution and depth dose on...

2015
Rezvan Azimi Parham Alaei Emiliano Spezi Susanta K. Hui

Orthovoltage irradiators are routinely used to irradiate specimens and small animals in biological research. There are several reports on the characteristics of these units for small field irradiations. However, there is limited knowledge about use of these units for large fields, which are essential for emerging large-field irregular shape irradiations, namely total marrow irradiation used as ...

2011
B. Azadbakht

Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...

2011
Sylvia Garny Werner Rühm Maria Zankl Franz M Wagner Herwig G Paretzke

BACKGROUND The Monte Carlo code GEANT4 was used to implement first steps towards a treatment planning program for fast-neutron therapy at the FRM II research reactor in Garching, Germany. Depth dose curves were calculated inside a water phantom using measured primary neutron and simulated primary photon spectra and compared with depth dose curves measured earlier. The calculations were performe...

Journal: :Medical physics 2011
Chang Heon Choi Hyon Soo Han Kwang-Jae Son Ul Jae Park Jun Sig Lee Won Ryang Wee Sung Whan Ha Il Han Kim Sung-Joon Ye

PURPOSE The potential of P-32 ophthalmic applicator irradiation after pterygium excision has been demonstrated as an alternative to Sr∕Y-90 irradiation. This study aimed to provide the clinical dosimetry for this new applicator. METHODS The prototype of a cylindrical P-32 applicator was fabricated according to the Monte Carlo (MC)-based design study. At a nominal activity of 6 mCi (0.22 GBq),...