2013
F Nordström

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4 dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept o...

2014
Mauro Valente José Vedelago

Fricke gel dosimetry is a valuable method for in-phantom dose measurements in complex irradiation modalities like IMRT and BNCT. Implementation of this dosimetry technique requires dedicated instruments capable of measuring and further analysis immediately in situ at the radiation facility. This work presents a novel and integral dosimetry system aimed to attain portability requirements. The me...

2012
Juan Azorín Nieto Juan Azorin Nieto

Radiation dosimetry is fundamental in Medical Physics, involving patients and phantom dosimetry. In both cases thennoluminescence dosimetry (TLD) is the most appropriate technique for measuring the absorbed dose. In this paper thennoluminescence phenomenon as well as the use of TLD in radiodiagnosis and radiotherapy for in vivo or in phantom measurements is discussed. Some results of measuremen...

2017
A. Mesbahi R. Naseri

Accuracy in the delivered dose to the patients plays an important and vital role in radiotherapy treatments. This happens because of steep gradient of dose-local control and dose-normal tissue complication probability curves. Dosimetric uncertainty of 3%-4% (one standard deviation) in the delivered dose to the target volume as an acceptable level has been recommended(1-3). In many centers, in v...

Bordera Gabriel Buendia Giménez Maribel Marti Marmol Gregorio Viera Morell Jiuia Oliva Parada Jorge Gaviria Pérez Maria de los Llanos

The use of high-power diode laser with a wavelength of 755 nm is an effective and safe method for the correction and partial and/or total elimination of pigmented lesions, specifically solar lentigines. This wavelength has yet not been used in diode lasers to treat solar lentigines. Side effects are the usual ones, including darkening and scab formation. Our patient was a 40-year-old woman of C...

Journal: :Journal of physics. Conference series 2009
Hs Sakhalkar D Sterling J Adamovics G Ibbott M Oldham

An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assurance. This work presents an investigation of the feasibility of PRESAGE/optical-CT 3D dosimetry in the Radiologic Physics Center (RPC) IMRT H&...

Journal: :journal of lasers in medical sciences 0
liu ying nanfang hospital, southern medical university, colleg of stomatology, southern medical university jie gao department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china. yan gao center of oral implantology, guangdong provincial stomatological hospital, southern medical university,510280 guangzhou, p.r. china. shuaimei xu department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china. xueling zhan department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china. buling wu department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china.

introduction: to investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (dh). methods: twenty extracted human third molars were selected to prepare dentin discs. ...

This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-P...