نتایج جستجو برای: electron dosimetry

تعداد نتایج: 315962  

Journal: :journal of biomedical physics and engineering 0
m. dehghan master student of physics, department of physics, yazd university, yazd, iran h. mokhtari assistant professor of physics, department of physics, yazd university, yazd, iran f. bouzarjomehri associate professor of medical physics, shahid sadoughi university of medical sciences, yazd, iran

background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...

Journal: :Physics open 2023

Electron paramagnetic resonance, thermoluminescence, and optically stimulated luminescence, with biological tissues inert materials are well established physical methods for retrospective dosimetry in acute accidental exposures. The objective of this article is to provide a view the questions still open, current challenges needed solutions. As research on emergency response encountering increas...

2014
Antony L Palmer David Bradley Andrew Nisbet

The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple-channel dosimetry has recently been utilized in exte...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2003
Daniela Kroutilķková Josef Novotný Libor Judas

INTRODUCTION The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. MATERIALS AND METHODS The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual re...

2017
Philip von Voigts-Rhetz Hilke Vorwerk Klemens Zink

Purpose: All present dosimetry protocols recommend well-guarded parallelplate ion chambers for electron dosimetry. For the guard-less Markus chamber, an energy dependent fluence perturbation correction pcav is given. This perturbation correction was experimentally determined by van der Plaetsen by comparison of the read-out of a Markus and a NACP chamber, which was assumed to be “perturbation-f...

Journal: :Retina 2014
Daniel Lavinsky Christopher Sramek Jenny Wang Philip Huie Roopa Dalal Yossi Mandel Daniel Palanker

PURPOSE Laser therapy for diabetic macular edema and other retinal diseases has been used within a wide range of laser settings: from intense burns to nondamaging exposures. However, there has been no algorithm for laser dosimetry that could determine laser parameters yielding a predictable extent of tissue damage. This multimodal imaging and structural correlation study aimed to verify and cal...

Journal: :Medical physics 1997
D S Followill D S Davis W F Hanson

Since 1984, the Radiological Physics Center (RPC) has used the American Association of Physicists in Medicine Task Group 21 (TG-21) protocol (absorbed dose determination) as the basis of its On-site Dosimetry Review visits to institutions participating in the National Cancer Institute's cooperative clinical trials. Subsequent to the TG-21 protocol, the Task Group 25 (TG-25) report on electron-b...

Journal: :iranian journal of radiation research 0
s.r.m. mahdavi department of medical physics, tehran university of medical sciences, tehran, iran m. mahdavi department of physics, faculty of basic sciences, mazandaran university, babolsar, iran h. alijanzadeh department of physics, faculty of basic sciences, mazandaran university, babolsar, iran m. zabihzadeh department of medical physics, joundishapour university of medical sciences, ahvaz, iran a. mostaar department of medical physics, faculty of medicine, shahid beheshti university of medical sciences, tehran, iran

background: two protocols of aapm tg-51 and iaea trs-398 were compared followed by a measurement and monte carlo simulation of beam quality correction factor, kq, aapm tg-51 and iaea trs-398 protocols were compared for the absorbed dose to water for dw, and kq parameters. materials and methods: dose measurements by either protocols were performed with cylindrical and plane parallel chambers for...

Journal: :International journal of radiation oncology, biology, physics 2004
Marnee M Spierer Linda X Hong Raquel T Wagman Matthew S Katz Rebecca L Spierer Beryl McCormick

PURPOSE To evaluate the technique, dosimetry, acute and late toxicity, local control (LC), and overall survival (OS) with the use of computed tomography (CT)-based postmastectomy electron beam therapy (PMEBT) in high-risk patients. METHODS AND MATERIALS From 1990 to 2000, 118 patients with pathologic stage I-IIIB breast cancer underwent PMEBT of the chest wall (CW) (n = 3), CW and supraclavic...

2002
Vadim CHUMAK

The paper is devoted to review of development and application of EPR dosimetry with teeth in Ukraine. It deals with specific features of the EPR dosimetry protocol, which was developed and is practically used in SCRM for retrospective dosimetry of clean-up workers (liquidators). Extensive methodological research was conducted in SCRM in order to develop an original version of EPR dosimetric pro...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید