The use of diagnostic reference levels (DRLs) is part of the optimisation process of radiation protection, in that it identifies practices that are in need of corrective action, resulting in dose reduction. Their use is provided for in Irish and European legislation. In this project, measurements were carried out at 42 of the 46 licensed intra-oral xray machines in Co. Wicklow using an Unfors M...
In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...
Sedimentation is one of the most important problems in harbors that results in considerable economic costs. Harbor planforms affects the flow pattern in the harbor basin and consequently, plays an important role in sediment transport and sedimentation. In the present study, a two dimensional depth-averaged hydrodynamic and sediment transport model has been developed to investigate the effect of...
BACKGROUND AND PURPOSE Although neuroembolization has recently spread quickly, sufficient attention has not been focused on the associated radiation exposure. The purpose of this research was to evaluate the patient's entrance skin dose (ESD) during neuroembolizations in 6 institutions. MATERIALS AND METHODS This study was approved by all of the 6 institutional review boards, and all of the p...
Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar and pelvic X-ray examinations in interior posterior positions generate a method chest dose reduction decrease radiation risk. Materials Methods: indirect measurement was used the research. tube output measured using RAD-CHECK Plus ionization chamber calculated via applying...
The objective of this study was to determine the Dose Area Product (DAP) for sample of 70 patients (40 Females and 30 Males) undergoing different types of digital radiography (DR) examinations at King Abdul-Aziz University Hospital (KAUH), Saudi Arabia. This study was done through implementing a quality control (QC) program initiated by The Center for Training and radiation protection, KAU. It ...
Conventional diagnostic X-ray units are used for radiographic imaging in many countries. For obtaining entrance surface doses, a numerical dose determination method has been applied in Japan. Although this technique is effective, it has to account for errors, particularly fluctuations, due to the beam quality and output of X-ray tubes. As a part of our quality control procedures, we recorded th...
A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...
Minute amounts of Locke's or Tyrode's solution have been brought into contact with the interstitial connective tissue of the skin of the living mouse, at atmospheric pressure, in such a manner that the blood or lymphatic vessels are not entered directly. Under such circumstances these absorbable fluids enter the tissue spontaneously. Entrance is strikingly intermittent, not continuous, and so t...