نتایج جستجو برای: goldmann applanation tonometer

تعداد نتایج: 2316  

2016
Dr Karthika Mohankumar Rashmi Jain Vidya Hegde

Purpose: To compare the Intra Ocular Pressure (IOP) measurements obtained by Applanation Tonometer (AT) & Rebound Tonometer (RT). Methods: The Central Corneal Thickness (CCT) corrected IOP of 100 eyes were measured using first with RT (I Care) followed by AT (GAT). Results were compared statistically using Bland –Altman plot & Deming’s regression analysis. Results: Scatter plot analysis showed ...

Journal: :Current Journal of Glaucoma Practice with DVD 2008

Journal: :Investigative ophthalmology & visual science 2011
William Lau David Pye

PURPOSE To examine the interrelationships among the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and corneal geometry measurements in a young, healthy sample. METHODS Central corneal radius, ORA, GAT, and central corneal thickness (CCT) measurements were taken in 99 subjects (age, 21 ± 2 years) who were free of ocular and ...

Journal: :Cornea 2010
Yakov Goldich Yaniv Barkana Isaac Avni David Zadok

PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a c...

2014
Mohammad Reza Razeghinejad Ramin Salouti Mohammad Reza Khalili

BACKGROUND To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. METHODS Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

Journal: :Investigative ophthalmology & visual science 2009
Afsun Sahin Atilla Bayer Gökhan Ozge Tarkan Mumcuoğlu

PURPOSE To investigate possible corneal biomechanical changes in patients with diabetes mellitus and understand the influence of such changes on intraocular pressure measurements. METHODS The study group was composed of 120 eyes from 61 healthy control subjects and 81 eyes from 43 diabetic subjects. IOP was measured first with an ocular response analyzer (ORA) and subsequently with a Goldmann...

Journal: :Journal of glaucoma 2010
Yeshigeta Gelaw Martin Kollmann Njuguna M Irungu Dunera R Ilako

BACKGROUND Estimates of intraocular pressure (IOP) are influenced directly by the central corneal thickness (CCT). We assume and apply a single value for CCT (520 μm) in applanation tonometry estimates, although there is compelling evidence that CCT varies between individuals. OBJECTIVE To determine the influence of CCT and other factors on IOP among Ethiopians. METHODS A cross sectional st...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید