Annette Haworth Duncan J. Butler Lisa Wilfert Martin A. Ebert Stephen P. Todd Anna J.M. Hayton Tomas Kron

For the purpose of dose measurement using a high-dose rate (192)Ir source, four methods of thermoluminescent dosimeter (TLD) calibration were investigated. Three of the four calibration methods used the (192)Ir source. Dwell times were calculated to deliver 1 Gy to the TLDs irradiated either in air or water. Dwell time calculations were confirmed by direct measurement using an ionization chambe...

2012
Travis T. Tollefson David White James Brookes Steven Goudy

1Department of Otolaryngology-Head and Neck Surgery, University of California Davis, Davis, CA 95817, USA 2Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, SC 29425, USA 3Department of Otolaryngology-Head and Neck Surgery, University of Calgary, Calgory, AB, Canada T2N 1N4 4Department of Otolaryngology-Head and Neck Surgery, Vanderbilt Univer...

Journal: :iranian journal of radiation research 0
m. hajizadeh saffar medical physics department, mashhad university of medical sciences, mashhad, iran m.r. ghavamnasiri h. gholamhosseinian

background: in radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. the attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. the field size, depth and ssd dependence of wedge factor have been assessed for 9mv radiations of neptun pc linear accelerator. materia...

Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...

2008
Tuathan P. O'Shea Mark J. Foley David Rajasekar Patrick A. Downes Wil van der Putten Margaret Moore Andrew Shearer

Electron-beam therapy is used to treat superficial tumors at a standard 100 cm source-to-surface distance (SSD). However, certain clinical situations require the use of an extended SSD. In the present study, Monte Carlo methods were used to investigate clinical electron beams, at standard and non-standard SSDs, from a Siemens Oncor Avant Garde (Siemens Healthcare, Erlangen, Germany) linear acce...

2017
A. Mesbahi

Monte Carlo (MC) method is the most accurate method for dose calculations in radiotherapy. It has been used in many applications including external photon and electron beam therapy, brachytherapy, etc. (1). MC method has overcome the deficiencies of analytical dose calculation methods in conditions such as tissue inhomogeneities and electronic disequilibrium with small fields(2-5). For the appl...

2014
N Mohammadi S H Miri-Hakimabad L Rafat-Motavalli

BACKGROUND High-energy linear accelerator (linac) is a valuable tool and the most commonly used device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of (γ,n) interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients undergoing radiation treatment and increase the risk of sec...

Journal: :World Journal of Engineering and Technology 2022

Purpose: To model the ELEKTA COMPACT accelerator head by using EGSnrc/BEAMnrc/DOSXYZnrc and to validatethe simulation according depth-dose lateral profiles of different radiation fields measured water phantom. Methods: IBA Blue Water Phantom2 CC13 Ionization Chamber were used measure curves at 10 cm × field profile depth underwater. In BEAMnrc, main components initial electron beam are establis...

E. Raeisi, H. Rajabi, S.M.R. Aghamiri,

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Tohru Shiga Yuichi Morimoto Naoki Kubo Norio Katoh Chietsugu Katoh Wataru Takeuchi Reiko Usui Kenji Hirata Shinichi Kojima Kikuo Umegaki Hiroki Shirato Nagara Tamaki

UNLABELLED An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images wit...