نتایج جستجو برای: hip prosthesis
تعداد نتایج: 88373 فیلتر نتایج به سال:
In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...
47 consecutive cases of fracture neck femur in patients older than 70 years were managed by cemented hemiarthroplasty with Austin Moore prosthesis at a tertiary care teaching hospital with the objectives of studying the short come outcome and to compare the results with standard studies using uncemented Austin Moore prosthesis, to determine if cementing the prosthesis improves clinical outcome....
BACKGROUND The treatment of elderly patients with Kashin-Beck disease (KBD) remains clinically challenging, and clinical data are very lacking. The aim of this study was to retrospectively evaluate pain and functional outcomes following total hip replacement in adult patients with severe KBD of the hip. METHODS Twenty-two patients (32 hips) with KBD underwent primary hip replacement and were ...
Background: Dislocation after total hip arthroplasty is a common complication and partially based on impingement. Questions/purposes: (1) The purpose of this study was to investigate the angle between anterior and posterior impingement in current hip cup designs. (2) Furthermore, the aim was to design a model of an acetabular cup with sparing gaps that match to impact areas. Methods: The range ...
Total hip replacement is an often-performed orthopedic surgical procedure; the amount of procedures undertaken will increase since our life expectancy is growing. In order to optimize function, hip biomechanics should be restored to as near normal as possible. The goal of this pilot study was to determine whether or not it is feasible to compute the vectorial hip reaction force pathways on the ...
Thrust plate prosthesis (TPP) has load-transferring characteristics different from those of conventional intramedullary stemmed prostheses (ISP). We investigate whether prosthesis type (intramedullary or extramedullary application) can improve early functional activities in hospital patients with hip arthroplasty. Early postoperative functional activities of 30 patients with TPP were compared w...
A 22 years patient with no significant pathological history consulted for right hip pain and total right lower limbs functional disability without general health deterioration a week before his hospitalization. Clinical examination performed at the time of admission objectified pain on palpation and after right hip mobilization. Plain radiography (A) and CT scan of the hip (B) objectified a rig...
The painful total hip arthroplasty requires careful evaluation and investigation. This is usually focused on the prosthesis and adjacent anatomical structures. We present a case report of a 64-year-old man who had a Birmingham hip resurfacing procedure for primary osteoarthritis. His hip pain worsened following the procedure and was under systematic investigation for this. Subsequent investiga...
Total wrist arthroplasty are not used as widely as total knee and hip replacement. The functional hands are requiring surgeons to design a durable and functional satisfying prosthesis. This article will list the main reasons that cause the failure of the prosthesis. Some remarkable and representative prostheses are listed to show the devolvement of total wrist prosthesis and their individual sp...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید