نتایج جستجو برای: homogeneous phantom
تعداد نتایج: 87222 فیلتر نتایج به سال:
background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
As a trilogy, this first paper along with the authors' two companion articles introduces alternate approaches to standard $R$-matrix parametrization of nuclear cross sections. The authors present evidence so-called shadow poles in theory for ${}^{134}$Xe. number and location depends upon how one continues operators complex wave numbers. also establish new pole sections, called $w\phantom{\rule{...
In this paper and an accompanying submission to $P\phantom{\rule{0}{0ex}}h\phantom{\rule{0}{0ex}}y\phantom{\rule{0}{0ex}}s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}l$ $R\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}v\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}w$ $L\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}t\ph...
Tunnel coupling is a key parameter in coupled semiconductor quantum dots, and crucial ingredient various device applications, such as exchange gates spin shuttling information processing. A widely used charge-sensing technique to extract the tunnel of double dot accounts for only ground orbital state each dot, but authors show that Si valley-orbit must be included analysis. With their more comp...
Key applications of quantum computing, including error correction, rely critically on the capability to measure (read out) state selected bits, without disturbing other qubits or terminating computation. Such $m\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}d\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}u\phantom{\rule{0}{...
Although there are many works on evaluating dose calculations of the anisotropic analytical algorithm (AAA) using various homogeneous and heterogeneous phantoms, related work concerning dosimetry due to tangential photon beam is lacking. In this study, dosimetry predicted by the AAA and collapsed cone convolution (CCC) algorithm was evaluated using the tangential photon beam and phantom geometr...
PURPOSE The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. METHODS Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linea...
Heterogeneities existing in the patient during treatment are neglected, as the treated subject is considered homogeneous in most of the commercially-available treatment planning systems (TPSs) used for high dose rate (HDR) brachytherapy. The choice of a suitable dosimeter for experimental dosimetry near the HDR source is crucial, mainly due to existence of steep dose gradients. The present work...
Spherical collapse of non-top-hat profiles in the presence of dark energy with arbitrary sound speed
We study the spherical collapse of non-top-hat matter fluctuations in presence dark energy with arbitrary sound speed. The model is described by a system partial differential equations solved using pseudo-spectral method collocation points. This can reproduce known analytical solutions linear regime an accuracy better than $10^{-6}\%$ and $10^{-2}\%$ for virialization threshold given usual mode...
BACKGROUND A major challenge in using magnetic resonance temperature imaging (MRTI) to monitor focused ultrasound (FUS) applications is achieving high spatio-temporal resolution over a large field of view (FOV). This is important to accurately monitor all ultrasound (US) power depositions. Magnetic resonance (MR) subsampling in conjunction with thermal model-based reconstruction of the MRTI uti...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید