نتایج جستجو برای: implant abutments

تعداد نتایج: 47154  

Journal: :The International journal of oral & maxillofacial implants 2001
S Wiseman G Tapia N Schaaf M Sullivan T Loree

Skin overgrowth of auricular implant abutments can be a difficult and frustrating problem, leading to multiple procedures and delaying the placement of a definitive prosthesis. In the present patient, plastic rings or "washers" were employed to successfully deal with this problem. A discussion of the management of peri-implant soft tissues is presented.

Journal: :The Journal of prosthetic dentistry 2007
Savvas Kamalakidis Gianluca Paniz Ki-Ho Kang Hiroshi Hirayama

Periodontal surgical procedures may not always offer a predictable level of success in the reproduction of a natural gingival architecture. Two different nonsurgical approaches are described for the management of soft tissue deficiencies in anterior implant-supported restorations. Clinically acceptable esthetic outcomes of anterior implant restorations can be achieved by using zirconium custom ...

2013
Luigi CANULLO Paulo G. COELHO Estevam A. BONFANTE

UNLABELLED Although the use of zirconia abutments for implant-supported restorations has gained momentum with the increasing demand for esthetics, little informed design rationale has been developed to characterize their fatigue behavior under different clinical scenarios. However, to prevent the zirconia from fracturing, the use of a titanium connection in bi-component aesthetic abutments has ...

2014
Erica Dorigatti de Avila Rafael Scaf de Molon Carlos Eduardo Vergani Francisco de Assis Mollo Vehid Salih

The aim of this review was to investigate the relationship between biofilm and peri-implant disease, with an emphasis on the types of implant abutment surfaces. Individuals with periodontal disease typically have a large amount of pathogenic microorganisms in the periodontal pocket. If the individuals lose their teeth, these microorganisms remain viable inside the mouth and can directly influen...

2013
Eun-Sook Kim Soo-Yeon Shin

PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, ...

2015
Ahmed I Mahrous Hussien A Aldawash Tarek A Soliman Fahad H Banasr Ahmed Abdelwahed

BACKGROUND This study was conducted to compare and evaluate the effect of two different attachments (locator attachment and ball and socket [B&S] attachment) on implants and natural abutments supporting structures, in cases of limited inter-arch spaces in mandibular Kennedy Class I implant supported removable partial over dentures by measuring the bone height changes through the cone beam radio...

Journal: :The International journal of oral & maxillofacial implants 2017
Marco Ferrari Michele Carrabba Alessandro Vichi Cecilia Goracci Maria Crysanti Cagidiaco

PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety pati...

Journal: :Journal of prosthodontics : official journal of the American College of Prosthodontists 2014
Sanjay Karunagaran Sony Markose Gregory Paprocki Russell Wicks

With an increase in the availability of implant restorative components, the selection of an appropriate implant abutment for a given clinical situation has become more challenging. This article describes a systematic protocol to help the practitioner more thoughtfully select abutments for single and multiple unit fixed implant prostheses. The article examines the evaluation, planning, design, a...

Journal: :Journal of applied biomechanics 2012
Kadir Firidinoğlu Suna Toksavul Muhittin Toman Mehmet Sarikanat Ibrahim Nergiz

The purpose of this study was to compare the fracture resistance and fracture mode of single implant-zirconium coping combinations using zirconium and titanium abutments and to analyze the stress distribution pattern using three-dimensional finite elements analysis. Twenty implants with titanium and zirconium abutments were randomly divided into two groups (n = 10) and into resin blocks. Zircon...

Journal: :The International journal of prosthodontics 2016
Gianpaolo Sannino Alberto Barlattani

PURPOSE The aim of this study was to evaluate and compare the use of straight versus angulated abutments on tilted implants in the All-on-Four immediate function protocol. MATERIALS AND METHODS A total of 85 patients (36 men and 49 women; mean age 56.5 years) with edentulous mandibles were treated according to the All-on-Four concept using computer-guided implant placement. All patients recei...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید