نتایج جستجو برای: micro ct image

تعداد نتایج: 604575  

Mohammad Yousefi Sooteh Parinaz Mehnati, Reza Malekzadeh

Introduction: Recently, the use of nanoparticles has increased for many purpose in medicine. One of these is using the nano particles in shields structure to protect sensitive organs such as breast which placed inside the field of chest CT scan and receives high dose. The aim of this study was the use of nano Bi2O3 to making shield for protection breast in chest CT examination ...

2010
R. Stoico S. Tassani F. Particelli F. Baruffaldi M. Viceconti

Aims The use of phantoms for micro-CT in biomedical research was already presented in literature for segmentation procedure, repeatability measures, densitometric calibration and in general for the improvement of micro-CT images [1-4]. Moreover, a high quality image was required to improve the accuracy of histomorphometric measurements. In particular these studies were performed for trabecular ...

Journal: :Development 2012
Michael D Wong Adrienne E Dorr Johnathon R Walls Jason P Lerch R Mark Henkelman

The goal of the International Mouse Phenotyping Consortium (IMPC) is to phenotype targeted knockout mouse strains throughout the whole mouse genome (23,000 genes) by 2021. A significant percentage of the generated mice will be embryonic lethal; therefore, phenotyping methods tuned to the mouse embryo are needed. Methods that are robust, quantitative, automated and high-throughput are attractive...

2016
H. Liu W. Li Y. S. Liu Y. S. Zhou

OBJECTIVES This study aims to evaluate if micro-CT can work as a method for the 3D assessment and analysis of cancellous bone by comparing micro-CT with undecalcified histological sections in OVX rats. METHODS The mandible and tibia of sham, ovariectomised (OVX) and zoledronate-injected ovariectomised (OVX-ZOL) rats were assessed morphometrically. Specimens were scanned by micro-CT. Undecalci...

Journal: :Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery 2017
Camilla Albeck Neldam Jon Sporring Alexander Rack Torsten Lauridsen Ellen-Margrethe Hauge Henrik L Jørgensen Niklas Rye Jørgensen Robert Feidenhansl Else Marie Pinholt

The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at...

Ali Shabestani Monfared, Gholam Reza Ataei Mohammad Davoudi Sara Delfan Shiva Shoubkolaei

Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...

2016
Jose Luis Ortiz Amparo Ortiz Javier Milara Miguel Armengot Celia Sanz Desamparados Compañ Esteban Morcillo Julio Cortijo

Different image techniques have been used to analyze mucociliary clearance (MCC) in humans, but current small animal MCC analysis using in vivo imaging has not been well defined. Bitter taste receptor (T2R) agonists increase ciliary beat frequency (CBF) and cause bronchodilation but their effects in vivo are not well understood. This work analyzes in vivo nasal and bronchial MCC in guinea pig a...

M A Mosleh-Shirazi M Keshtkar, V Saba,

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

Journal: :Medical physics 2006
Marc Kachelriess Katia Sourbelle Willi A Kalender

We propose an empirical cupping correction (ECC) algorithm to correct for CT cupping artifacts that are induced by nonlinearities in the projection data. The method is raw data based, empirical, and requires neither knowledge of the x-ray spectrum nor of the attenuation coefficients. It aims at linearizing the attenuation data using a precorrection function of polynomial form. The coefficients ...

Journal: :AJR. American journal of roentgenology 2006
Srinivasan Mukundan Ketan B Ghaghada Cristian T Badea Chen-Yu Kao Laurence W Hedlund James M Provenzale G Allan Johnson Emmanuel Chen Ravi V Bellamkonda Ananth Annapragada

OBJECTIVE The goal of this study was to determine if an iodinated, liposomal contrast agent could be used for high-resolution, micro-CT of low-contrast, small-size vessels in a murine model. MATERIALS AND METHODS A second-generation, liposomal blood pool contrast agent encapsulating a high concentration of iodine (83-105 mg I/mL) was evaluated. A total of five mice weighing between 20 and 28 ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید